[Foreign body retained within ulnar nerve in the distal humerus].

M Pleser1, A Müller, J Veltin, J Ludwig.   

Abstract

This report describes the procedures applied to remove a metal foreign body retained inside the ulnar nerve in the distal humerus of a 49-year-old patient. Exemplified by an unfavorable primary treatment this article presents the first description of removal of an foreign body retained within a nerve whereby emphasis is placed on the problems associated with the preoperative and intraoperative localization of the foreign particle.

Entities:  

Mesh:

Year:  2014        PMID: 23949193     DOI: 10.1007/s00113-013-2482-2

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  5 in total

1.  Median nerve injury caused by missed foreign body. Case report.

Authors:  C Rainer; T Schoeller; G Wechselberger; T Bauer; H Hussl
Journal:  Scand J Plast Reconstr Surg Hand Surg       Date:  2000-12

2.  Acute median nerve injury due to migration of a Kirschner wire.

Authors:  I M Jou; K A Lai
Journal:  J Hand Surg Br       Date:  1998-02

3.  Isolated laceration to the deep motor branch of the ulnar nerve by a retained foreign body.

Authors:  Alison Kitay; Scott S Wolfe
Journal:  Am J Orthop (Belle Mead NJ)       Date:  2012-08

4.  Occult injury of the median nerve.

Authors:  D K Faithfull; J F Petchell
Journal:  J Hand Surg Br       Date:  1995-04

5.  Ultrasound examination in the surgical treatment for upper extremity peripheral nerve injuries: part I.

Authors:  Cengiz Cokluk; Keramettin Aydin
Journal:  Turk Neurosurg       Date:  2007-10       Impact factor: 1.003

  5 in total
  1 in total

1.  Foreign Body Inside the Tunnel: A Rare Cause of Acute Cubital Tunnel Syndrome.

Authors:  Gokce Yildiran; Mustafa Sutcu; Osman Akdag; Zekeriya Tosun
Journal:  Surg J (N Y)       Date:  2019-10-28
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.