Literature DB >> 23948245

Modified carbon paste sensor for the potentiometric determination of neostigmine bromide in pharmaceutical formulations, human plasma and urine.

A F Khorshid1, Y M Issa.   

Abstract

A novel, simple, rapid, selective and sensitive method for the determination of neostigmine (Ns) ion in its bulk powder, different pharmaceutical dosage forms, and biological fluids (plasma and urine) using four modified carbon paste electrodes was developed. Sensor 1 is based on ion-association Ns-TPB, sensor 2 used Ns-PT, sensor 3 comprises a mixture of (Ns-PT+Ns-TPB) and sensor 4 was constructed using (Ns-PT+β-CD). Solvent mediator 2-NPPE exhibited a proper behavior including Nernstian slope ranging from 61.5±0.5 to 64.5±0.5 mV per decade over the pH range of 3.8-10 for the four sensors. Linear responses of Ns within the concentration range 1.0×10(-7)-1.0×10(-2) mol/L were obtained. The response time is very short (≤10s) with a detection limit 6.3×10(-8) M. In flow injection analysis (FIA), sensor 3 shows a Nernstian slope value 75.5±0.5 mV per decade within the concentration range of 1×10(-6)-1×10(-2) mol/L and with a detection limit 7.5×10(-7) mol/L. The utility of mixed or additives of β-CD had a significant influence on increasing the sensitivity of sensors 3 and 4 compared to sensors 1 and 2. The sensors were applied for the determination of neostigmine (Ns) ion in its bulk powder, different pharmaceutical dosage forms, and biological fluids (plasma and urine). The results obtained were satisfactory with excellent percentage recovery comparable with official method for the assay based on non-aqueous titration using perchloric acid as a titrant.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Carbon-paste electrode; Flow injection analysis; Ion-associate; Neostigmine bromide; Potentiometry; Sensor

Mesh:

Substances:

Year:  2013        PMID: 23948245     DOI: 10.1016/j.bios.2013.07.018

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

Review 1.  Potentiometric sensors for the determination of pharmaceutical drugs.

Authors:  Islam M Mostafa; Chengda Meng; Zixuan Dong; Baohua Lou; Guobao Xu
Journal:  Anal Sci       Date:  2022-02-28       Impact factor: 2.081

2.  New Electrochemically-Modified Carbon Paste Inclusion β-Cyclodextrin and Carbon Nanotubes Sensors for Quantification of Dorzolamide Hydrochloride.

Authors:  Nawal Ahmad Alarfaj; Maha Farouk El-Tohamy
Journal:  Int J Mol Sci       Date:  2016-12-02       Impact factor: 5.923

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.