Literature DB >> 23947480

Tubule density and diameter in coronal dentin from primary and permanent human teeth.

Tathiane L Lenzi1, Camila de Almeida B Guglielmi, Victor E Arana-Chavez, Daniela P Raggio.   

Abstract

This study compared dentinal tubule density and diameter of human primary and permanent teeth at different depths of the coronal dentin. Crowns of eight primary second molars and eight permanent third molars were serially sectioned into three disks of ~0.5 mm thickness (superficial, middle, and deep layers), perpendicular to the long axis. Tubule density and diameter were evaluated in 2,000× and 3,000× magnifications by scanning electron microscopy. Data obtained were subjected to two-way repeated measures ANOVA and Tukey's post hoc test (α = 0.05). Tubule density was greater in primary teeth compared with permanent ones, regardless of depth (primary: 124,329 ± 43,594 mm2; permanent: 45,972 ± 21,098 mm2). In general, the tubule density increased as the dentin depth increased, except to the superficial and middle layers from permanent teeth. Tubule diameter was larger in the dentin layer close to the pulp chamber (superficial: 2.4 ± 0.07 μm; middle: 3.70 ± 0.06 μm; deep: 4.28 ± 0.04 μm). No difference was observed between primary (3.48 ± 0.81 μm) and permanent teeth (3.47 ± 0.73 μm). The tubule diameter increases as the dentin depth increases for primary and permanent teeth; however, the tubule density is higher in primary teeth.

Entities:  

Mesh:

Year:  2013        PMID: 23947480     DOI: 10.1017/S1431927613012725

Source DB:  PubMed          Journal:  Microsc Microanal        ISSN: 1431-9276            Impact factor:   4.127


  14 in total

1.  Effect of green tea-loaded chitosan nanoparticles on leathery dentin microhardness.

Authors:  Fabiana Almeida Curylofo-Zotti; Antonio Claudio Tedesco; Gustavo Teodoro Costa Lizarelli; Luandra Aparecida Unten Takahashi; Silmara Aparecida Milori Corona
Journal:  Odontology       Date:  2021-05-08       Impact factor: 2.634

2.  [Effects of three self-etch adhesives and mild salivary contamination on the bonding durability of deciduous teeth].

Authors:  C Y Luo; C F Peng; Y Yang; M Qin; Y Y Wang
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-12-09

3.  Degradation of resin-dentine bond of different adhesive systems to primary and permanent dentine.

Authors:  F Z M Soares; T L Lenzi; R de Oliveira Rocha
Journal:  Eur Arch Paediatr Dent       Date:  2017-03-07

Review 4.  The use of fluoride for the prevention of dental erosion and erosive tooth wear in children and adolescents.

Authors:  A Lussi; M A R Buzalaf; D Duangthip; V Anttonen; C Ganss; S H João-Souza; T Baumann; T S Carvalho
Journal:  Eur Arch Paediatr Dent       Date:  2019-02-14

5.  Characterization of primary and permanent teeth using terahertz spectroscopy.

Authors:  K Kamburoğlu; N Ö Yetimoĝlu; H Altan
Journal:  Dentomaxillofac Radiol       Date:  2014-06-18       Impact factor: 2.419

6.  3D Maskless Micropatterning for Regeneration of Highly Organized Tubular Tissues.

Authors:  Chi Ma; Tiejun Qu; Bei Chang; Yan Jing; Jerry Q Feng; Xiaohua Liu
Journal:  Adv Healthc Mater       Date:  2017-11-09       Impact factor: 9.933

7.  Primer application technique and remaining dentin thickness affected microtensile bond strength of contemporary dentin adhesives under simulated pulp pressure.

Authors:  Paphawee Somrit; Yanee Tantilertanant; Sirivimol Srisawasdi
Journal:  Clin Oral Investig       Date:  2022-09-16       Impact factor: 3.606

8.  Zinc oxide eugenol paste jeopardises the adhesive bonding to primary dentine.

Authors:  C W Pires; T L Lenzi; F Z M Soares; R O Rocha
Journal:  Eur Arch Paediatr Dent       Date:  2018-05-12

9.  Evaluation of the Diode laser (810nm,980nm) on dentin tubule diameter following internal bleaching.

Authors:  Nazanin Kiomarsi; Soheil Salim; Pegah Sarraf; Mohammad Javad-Kharazifard; Nasim Chiniforush
Journal:  J Clin Exp Dent       Date:  2016-07-01

10.  Microtensile Bond Strength of Fiber-Reinforced and Particulate Filler Composite to Coronal and Pulp Chamber Floor Dentin.

Authors:  Anja Baraba; Samir Cimic; Matteo Basso; Andrei C Ionescu; Eugenio Brambilla; Ivana Miletić
Journal:  Materials (Basel)       Date:  2021-05-05       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.