Literature DB >> 23945890

Comparison of prophylactic effects of polyurethane cylindrical or tapered cuff and polyvinyl chloride cuff endotracheal tubes on ventilator-associated pneumonia.

Ata Mahmoodpoor1, Ali Peyrovi-far, Hadi Hamishehkar, Zhaleh Bakhtyiari, Mir Mousa Mirinezhad, Masoud Hamidi, Samad Eslam Jamal Golzari.   

Abstract

Because microaspiration of contaminated supraglottic secretions past the endotracheal tube cuff is considered to be central in the pathogenesis of pneumonia, improved design of tracheal tubes with new cuff material and shape have reduced the size and number of folds, which together with the addition of suction ports above the cuff to drain pooled subglottic secretions leads to reduced aspiration of oropharyngeal secretions. So we conducted a study to compare the prophylactic effects of polyurethane-cylindrical or tapered cuff and polyvinyl chloride cuff endotracheal tubes (ETT) on ventilator-associated pneumonia. This randomized clinical trial was carried out in a 12 bed surgical intensive care unit. 96 patients expected to require mechanical ventilation more than 96 hours were randomly allocated to one of three following groups: Polyvinyl chloride cuff (PCV) ETT, Polyurethane (PU) cylindrical Sealguard ETT and PU Taperguard ETT. Cuff pressure monitored every three hours 3 days in all patients. Mean cuff pressure didn't have significant difference between three groups during 72 hours. Pneumonia was seen in 11 patients (34%) in group PVC, 8 (25%) in Sealguard and 7 (21%) in Taperguard group. Changes in mean cuff pressure between Sealguard and PVC tubes and also between Taperguard and PVC tubes did not show any significant difference. There was no significant difference in overinflation between three groups. The use of ETT with PU material results in reducing ventilator-associated pneumonia compared to ETT with PVC cuff. In PU tubes Taperguard has less incidence of ventilator-associated pneumonia compared to Sealguard tubes.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23945890

Source DB:  PubMed          Journal:  Acta Med Iran        ISSN: 0044-6025


  10 in total

1.  Randomized Pilot Trial of Two Modified Endotracheal Tubes To Prevent Ventilator-associated Pneumonia.

Authors:  Steven Deem; David Yanez; Laura Sissons-Ross; Jo Ann Elrod Broeckel; Stephen Daniel; Miriam Treggiari
Journal:  Ann Am Thorac Soc       Date:  2016-01

2.  The lowest effective intracuff pressure of the esophagus obstruction tube to prevent reflux of gastric contents: a study on rabbits.

Authors:  LinLi Luo; Huafeng Li; LiangXue Zhou; Jun Zhou; Juan Ni; Rong Zhou
Journal:  J Anesth       Date:  2013-12-04       Impact factor: 2.078

3.  Evaluation of audible leak versus pressure volume loop closure for polyvinyl chloride cuff and polyurethane microcuff in endotracheal tube inflated with air: a prospective randomized study.

Authors:  Prashant Kumar; Jyoti Sharma; Kiranpreet Kaur; Mamta Bharadwaj; Anu Singh
Journal:  Med Gas Res       Date:  2021 Jan-Mar

4.  Ventilator-associated pneumonia in patients admitted to intensive care units, using open or closed endotracheal suctioning.

Authors:  Hadi Hamishekar; Kamran Shadvar; Majid Taghizadeh; Samad Ej Golzari; Mojtaba Mojtahedzadeh; Hassan Soleimanpour; Ata Mahmoodpoor
Journal:  Anesth Pain Med       Date:  2014-09-17

Review 5.  How to avoid microaspiration? A key element for the prevention of ventilator-associated pneumonia in intubated ICU patients.

Authors:  Stijn I Blot; Jan Poelaert; Marin Kollef
Journal:  BMC Infect Dis       Date:  2014-11-28       Impact factor: 3.090

6.  Comparison of pressure vs. volume controlled ventilation on oxygenation parameters of obese patients undergoing laparoscopic cholecystectomy.

Authors:  Reza Movassagi; Majid Montazer; Ata Mahmoodpoor; Vahid Fattahi; Afshin Iranpour; Sarvin Sanaie
Journal:  Pak J Med Sci       Date:  2017 Sep-Oct       Impact factor: 1.088

Review 7.  Tapered Cuff versus Conventional Cuff for Ventilator-Associated Pneumonia in Ventilated Patients: A Meta-Analysis of Randomized Controlled Trials.

Authors:  Wei Min Huang; Xu An Huang; Yan Ping Du; Liu Xia Li; Fang Fang Wu; Shao Qing Hong; Fang Xuan Tang; Zhang Qiang Ye
Journal:  Can Respir J       Date:  2019-01-22       Impact factor: 2.409

8.  Response to: Comment on "Tapered Cuff versus Conventional Cuff for Ventilator-Associated Pneumonia in Ventilated Patients: A Meta-Analysis of Randomized Controlled Trials".

Authors:  Xu An Huang; Wei Min Huang; Yan Ping Du; Liu Xia Li; Fang Fang Wu; Shao Qing Hong; Fang Xuan Tang; Zhang Qiang Ye
Journal:  Can Respir J       Date:  2020-02-13       Impact factor: 2.409

9.  Comparison of polyurethane tracheal tube cuffs and conventional polyvinyl chloride tube cuff for prevention of ventilator-associated pneumonia: A systematic review with meta-analysis.

Authors:  Minami Saito; Koichi Maruyama; Takahiro Mihara; Hiroshi Hoshijima; Go Hirabayashi; Tomio Andoh
Journal:  Medicine (Baltimore)       Date:  2021-03-05       Impact factor: 1.817

10.  Insights on the role of antimicrobial cuffed endotracheal tubes in preventing transtracheal transmission of VAP pathogens from an in vitro model of microaspiration and microbial proliferation.

Authors:  Joel Rosenblatt; Ruth Reitzel; Ying Jiang; Ray Hachem; Issam Raad
Journal:  Biomed Res Int       Date:  2014-04-10       Impact factor: 3.411

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.