Literature DB >> 23940855

A novel fluoroscopy-free, resuscitative endovascular aortic balloon occlusion system in a model of hemorrhagic shock.

Daniel J Scott1, Jonathan L Eliason, Carole Villamaria, Jonathan J Morrison, Robert Houston, Jerry R Spencer, Todd E Rasmussen.   

Abstract

BACKGROUND: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a potentially lifesaving maneuver in the setting of hemorrhagic shock. However, emergent use of REBOA is limited by existing technology, which requires large sheath arterial access and fluoroscopy-guided balloon positioning. The objectives of this study were to describe a new, fluoroscopy-free REBOA system and to compare its efficacy to existing technology. An additional objective was to characterize the survivability of 60 minutes of REBOA using these systems in a model of hemorrhagic shock.
METHODS: Swine (70-88 kg) in shock underwent 60 minutes of REBOA using either a self-centering, one component prototype balloon system (PBS, n = 8) inserted (8 Fr) and inflated without fluoroscopy or a two-component, commercially available balloon system (CBS, n = 8) inserted (14 Fr) with fluoroscopic guidance. Following REBOA, resuscitation occurred for 48 hours with blood, crystalloid, and vasopressors. End points included accurate balloon positioning, hemodynamics, markers of ischemia, resuscitation requirements, and mortality.
RESULTS: Posthemorrhage mean arterial pressure (mm Hg) was similar in the CBS and PBS groups (35 [8] vs. 34 [5]; p = 0.89). Accurate balloon positioning and inflation occurred in 100% of the CBS and 88% of the PBS group. Following REBOA, mean arterial pressure increased comparably in the CBS and PBS groups (81 [20] vs. 89 [16]; p = 0.21). Lactate peaked in the CBS and PBS groups (10.8 [1.4] mmol/L vs. 13.2 [2.1] mmol/L; p = 0.01) 45 minutes following balloon deflation but returned to baseline by 24 hours. Mortality was similar between the CBS and PBS groups (12% vs. 25%, p = 0.50).
CONCLUSION: This study reports the feasibility and efficacy of a novel, fluoroscopy-free REBOA system in a model of shock. Despite a significant physiologic insult, 60 minutes of REBOA is tolerated and recoverable. Development of lower profile, fluoroscopy-free endovascular balloon occlusion catheters may allow proactive aortic control in patients at risk for hemorrhagic shock and cardiovascular collapse.

Entities:  

Mesh:

Year:  2013        PMID: 23940855     DOI: 10.1097/ta.0b013e3182946746

Source DB:  PubMed          Journal:  J Trauma Acute Care Surg        ISSN: 2163-0755            Impact factor:   3.313


  25 in total

Review 1.  Advances in damage control resuscitation and surgery: implications on the organization of future military field forces.

Authors:  Homer Tien; Andrew Beckett; Naisan Garraway; Max Talbot; Dylan Pannell; Thamer Alabbasi
Journal:  Can J Surg       Date:  2015-06       Impact factor: 2.089

2.  Resuscitative endovascular balloon occlusion of the aorta: what is the optimum occlusion time in an ovine model of hemorrhagic shock?

Authors:  V A Reva; Y Matsumura; T Hörer; D A Sveklov; A V Denisov; S Y Telickiy; A B Seleznev; E R Bozhedomova; J Matsumoto; I M Samokhvalov; J J Morrison
Journal:  Eur J Trauma Emerg Surg       Date:  2016-10-13       Impact factor: 3.693

3.  Nationwide Analysis of Resuscitative Endovascular Balloon Occlusion of the Aorta in Civilian Trauma.

Authors:  Bellal Joseph; Muhammad Zeeshan; Joseph V Sakran; Mohammad Hamidi; Narong Kulvatunyou; Muhammad Khan; Terence O'Keeffe; Peter Rhee
Journal:  JAMA Surg       Date:  2019-06-01       Impact factor: 14.766

4.  Fixed-Distance Model for Balloon Placement During Fluoroscopy-Free Resuscitative Endovascular Balloon Occlusion of the Aorta in a Civilian Population.

Authors:  Pierre Pezy; Alexandros N Flaris; Nicolas J Prat; François Cotton; Peter W Lundberg; Jean-Louis Caillot; Jean-Stéphane David; Eric J Voiglio
Journal:  JAMA Surg       Date:  2017-04-01       Impact factor: 14.766

5.  Morphometric roadmaps to improve accurate device delivery for fluoroscopy-free resuscitative endovascular balloon occlusion of the aorta.

Authors:  Jason N MacTaggart; William E Poulson; Maheen Akhter; Andreas Seas; Katherine Thorson; Nick Y Phillips; Anastasia S Desyatova; Alexey V Kamenskiy
Journal:  J Trauma Acute Care Surg       Date:  2016-06       Impact factor: 3.313

Review 6.  Expanding the field of acute care surgery: a systematic review of the use of resuscitative endovascular balloon occlusion of the aorta (REBOA) in cases of morbidly adherent placenta.

Authors:  R Manzano-Nunez; M F Escobar-Vidarte; M P Naranjo; F Rodriguez; P Ferrada; J D Casallas; C A Ordoñez
Journal:  Eur J Trauma Emerg Surg       Date:  2017-09-19       Impact factor: 3.693

Review 7.  [Resuscitative endovascular balloon occlusion of the aorta : Option for incompressible trunk bleeding?]

Authors:  J Knapp; M Bernhard; T Haltmeier; D Bieler; B Hossfeld; M Kulla
Journal:  Anaesthesist       Date:  2018-04       Impact factor: 1.041

8.  Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) for Severe Torso Trauma in Japan: A Descriptive Study.

Authors:  Shokei Matsumoto; Kei Hayashida; Taku Akashi; Kyoungwon Jung; Kazuhiko Sekine; Tomohiro Funabiki; Takashi Moriya
Journal:  World J Surg       Date:  2019-07       Impact factor: 3.352

Review 9.  A small case series of aortic balloon occlusion in trauma: lessons learned from its use in ruptured abdominal aortic aneurysms and a brief review.

Authors:  T M Hörer; P Skoog; A Pirouzram; K F Nilsson; T Larzon
Journal:  Eur J Trauma Emerg Surg       Date:  2015-09-28       Impact factor: 3.693

Review 10.  Resuscitative endovascular balloon occlusion of the aorta in combat casualties: The past, present, and future.

Authors:  Sarah C Stokes; Christina M Theodorou; Scott A Zakaluzny; Joseph J DuBose; Rachel M Russo
Journal:  J Trauma Acute Care Surg       Date:  2021-08-01       Impact factor: 3.697