Guanhao Wu1, Mayumi Takahashi, Hajime Inaba, Kaoru Minoshima.
Abstract
A synthetic-wavelength interferometry of optical frequency combs is proposed for the pulse-to-pulse alignment in absolute distance measurement. The synthetic wavelength derived from the virtual second harmonic and the real second harmonic is used to bridge the interference intensity peak-finding method and the heterodyne interferometric phase measurement, so that the pulse-to-pulse alignment can be linked directly to single-wavelength heterodyne interferometry. The experimental results demonstrate that the distance measured by the peak-finding method with micrometer accuracy can be improved to the nanometer level by applying the method proposed.Year: 2013 PMID: 23939003 DOI: 10.1364/OL.38.002140
Source DB: PubMed Journal: Opt Lett ISSN: 0146-9592 Impact factor: 3.776