An endoscopic system adopting a liquid crystal lens with an electrically tunable depth-of-field.

Hung-Shan Chen1, Yi-Hsin Lin.   

Abstract

Conventional endoscopic systems consisting of several solid lenses suffer from a fixed and limited depth-of-field (DOF). For practical applications, conventional endoscopes mechanically change the distance between the solid lenses of a lens module in order to change the focusing plane and DOF to see clearly in a scene. In this paper, we demonstrate an electrically tunable endoscopic system adopting a liquid crystal lens. By means of tunable focusing properties of the LC lens as a positive lens and a negative lens, the object at different objective distances can be imaged to the image sensor clearly and the corresponding depth-of-field can also help to enlarge the total spatial depth perception in a scene. The optical mechanism is discussed. In the experiments, under adjustment of three discrete lens powers of the LC lens, the viewing range or total spatial depth perception of the endoscopic system is from 76.4 mm to 12.4 mm which is 2x improved compared to the conventional one without LC lens. We believe this study can be extended to the applications of industrial and medical endoscopes.

Entities:  

Mesh:

Year:  2013        PMID: 23938679     DOI: 10.1364/OE.21.018079

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  3 in total

1.  Five-dimensional two-photon volumetric microscopy of in-vivo dynamic activities using liquid lens remote focusing.

Authors:  Kayvan Forouhesh Tehrani; Charles V Latchoumane; W Michael Southern; Emily G Pendleton; Ana Maslesa; Lohitash Karumbaiah; Jarrod A Call; Luke J Mortensen
Journal:  Biomed Opt Express       Date:  2019-06-26       Impact factor: 3.732

2.  Optical axial scanning in confocal microscopy using an electrically tunable lens.

Authors:  Joey M Jabbour; Bilal H Malik; Cory Olsovsky; Rodrigo Cuenca; Shuna Cheng; Javier A Jo; Yi-Shing Lisa Cheng; John M Wright; Kristen C Maitland
Journal:  Biomed Opt Express       Date:  2014-01-30       Impact factor: 3.732

3.  High-Quality Large-Magnification Polymer Lens from Needle Moving Technique and Thermal Assisted Moldless Fabrication Process.

Authors:  Ratthasart Amarit; Atcha Kopwitthaya; Prasit Pongsoon; Ungkarn Jarujareet; Kosom Chaitavon; Supanit Porntheeraphat; Sarun Sumriddetchkajorn; Thaweesak Koanantakool
Journal:  PLoS One       Date:  2016-01-14       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.