Literature DB >> 23935033

Plasma protein denaturation with graded heat exposure.

R Vazquez1, D F Larson.   

Abstract

During cardiopulmonary bypass (CPB), perfusion at tepid temperatures (33-35 °C) is recommended to avoid high temperature cerebral hyperthermia during and after the operation. However, the ideal temperature for uncomplicated adult cardiac surgery is an unsettled question. Typically, the heat exchanger maximum temperature is monitored between 40-42 °C to prevent denaturation of plasma proteins, but studies have not been performed to make these conclusions. Therefore, our hypothesis was to determine the temperature in which blood plasma protein degradation occurs after 2 hours of heat exposure. As a result, blood plasma proteins were exposed to heat in the 37-50 °C range for 2 hours. Plasma protein samples were loaded onto an 8-12% gradient gel for SDS-PAGE and low molecular weight plasma protein degradation was detected with graded heat exposure. Protein degradation was first detected between 43-45 °C of heat exposure. This study supports the practice of monitoring the heat exchanger between 40-42 °C to prevent denaturation of plasma proteins.

Entities:  

Keywords:  SDS-PAGE; degradation; denaturation; heat exposure; plasma protein

Mesh:

Substances:

Year:  2013        PMID: 23935033     DOI: 10.1177/0267659113498921

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  6 in total

1.  The N-terminal MYB domains affect the stability and folding aspects of Arabidopsis thaliana MYB4 transcription factor under thermal stress.

Authors:  Mehali Mitra; Puja Agarwal; Sujit Roy
Journal:  Protoplasma       Date:  2021-01-05       Impact factor: 3.356

2.  Ho:YAG laser and temperature: is it safe to use high-power settings?

Authors:  Daniele Robesti; Luca Villa; Paola Saccomandi; Olivier Traxer; Andrea Salonia; Eugenio Ventimiglia
Journal:  World J Urol       Date:  2022-04-19       Impact factor: 4.226

3.  Modeling microbial ethanol production by S. aureus, K. pneumoniae, and E. faecalis under aerobic/anaerobic conditions - applicability to laboratory cultures and real postmortem cases.

Authors:  Glykeria Velivasi; Nikolaos Kourkoumelis; Iraklis Sakkas; Vassiliki A Boumba
Journal:  Int J Legal Med       Date:  2021-08-10       Impact factor: 2.686

4.  Effect of Temperature and Flow Rate on the Cell-Free Area in the Microfluidic Channel.

Authors:  Angeles Ivón Rodríguez-Villarreal; Manuel Carmona-Flores; Jordi Colomer-Farrarons
Journal:  Membranes (Basel)       Date:  2021-02-03

5.  Rapid dry plasma thawing system: An alternative to conventional thawing baths.

Authors:  S Sanooja Pinki; Ganesh Mohan; Aboobacker Mohamed Rafi; Susheela Jacob Innah; Tom Thomas
Journal:  Asian J Transfus Sci       Date:  2017 Jul-Dec

6.  Effect of Fluid Flow Rate on Efficacy of Fluid Warmer: An In Vitro Experimental Study.

Authors:  Vorasruang Thongsukh; Chanida Kositratana; Aree Jandonpai
Journal:  Anesthesiol Res Pract       Date:  2018-07-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.