Literature DB >> 23932845

Use of IAEA's phase-space files for the implementation of a clinical accelerator virtual source model.

Alexis Rucci1, Claudia Carletti2, Walter Cravero2, Bojan Strbac3.   

Abstract

In the present work, phase-space data files (phsp) provided by the International Atomic Energy Agency (IAEA) for different accelerators were used in order to develop a Virtual Source Model (VSM) for clinical photon beams. Spectral energy distributions extracted from supplied phsp files were used to define the radiation pattern of a virtual extended source in a hybrid model which is completed with a virtual diaphragm used to simulate both electron contamination and the shape of the penumbra region. This simple virtual model was used as the radiation source for dosimetry calculations in a water phantom. The proposed model proved easy to build and test, and good agreement with clinical accelerators dosimetry measurements were obtained for different field sizes. Our results suggest this simple method could be useful for treatment planning systems (TPS) verification purposes.
Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  IAEA; Monte Carlo; Phase-space; Radiotherapy; Virtual source model

Mesh:

Year:  2013        PMID: 23932845     DOI: 10.1016/j.ejmp.2013.07.127

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  5 in total

1.  Monte Carlo simulation using PRIMO code as a tool for checking the credibility of commissioning and quality assurance of 6 MV TrueBeam STx varian LINAC.

Authors:  M Arif Efendi; Amporn Funsian; Thawat Chittrakarn; Tripob Bhongsuwan
Journal:  Rep Pract Oncol Radiother       Date:  2019-12-20

2.  Frequency-dependent optimal weighting approach for megavoltage multilayer imagers.

Authors:  Ingrid Valencia Lozano; Mengying Shi; Marios Myronakis; Paul Baturin; Rony Fueglistaller; Pascal Huber; Mathias Lehmann; Daniel Morf; Dianne Ferguson; Matthew W Jacobson; Thomas Harris; Ross I Berbeco; Christopher L Williams
Journal:  Phys Med Biol       Date:  2021-04-16       Impact factor: 4.174

3.  A phase space model of a Versa HD linear accelerator for application to Monte Carlo dose calculation in a real-time adaptive workflow.

Authors:  James L Bedford; Rahul Nilawar; Simeon Nill; Uwe Oelfke
Journal:  J Appl Clin Med Phys       Date:  2022-06-14       Impact factor: 2.243

4.  Rounded leaf end effect of multileaf collimator on penumbra width and radiation field offset: an analytical and numerical study.

Authors:  Dong Zhou; Hui Zhang; Peiqing Ye
Journal:  Radiol Oncol       Date:  2015-08-21       Impact factor: 2.991

5.  Lateral Penumbra Modelling Based Leaf End Shape Optimization for Multileaf Collimator in Radiotherapy.

Authors:  Dong Zhou; Hui Zhang; Peiqing Ye
Journal:  Comput Math Methods Med       Date:  2016-01-19       Impact factor: 2.238

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.