Literature DB >> 23932822

Percutaneous anterior occiput-to-axis screw fixation: technique aspects and case series.

Ai M Wu1, Yong L Chi, Wei Weng, Hua Z Xu, Xiang Y Wang, Wen F Ni.   

Abstract

BACKGROUND CONTEXT: Posterior occipitocervical fusion techniques have been previously described; however, traditional open anterior approaches are plagued by exposure difficulty. A minimally invasive percutaneous anterior occipitocervical fixation approach avoids this difficult exposure procedure.
PURPOSE: This article describes a novel technique of percutaneous anterior occiput-to-axis screw fixation and its clinical outcomes. STUDY
DESIGN: Technique report.
METHODS: Anteroposterior, lateral and open-mouth views, and computed tomography scans are preoperatively obtained to appraise the feasibility of surgery. We extend our experience of using percutaneous anterior transarticular screw fixation to occiput-to-axis screw fixation. This procedure was performed on six patients.
RESULTS: The operation was successfully performed on all patients without technical difficulties, and no vertebral artery, nerve injury or soft tissue (such as esophageal) complications occurred. All six patients followed up 10 to 39 months (averaged 20.5 months). Bone union was achieved in five patients, and the one patient lacking bone union was stable at final follow-up. The syringomyelia of four patients is almost complete reduction. No screw loosening or breakage has occurred.
CONCLUSIONS: With the correct puncture point, angle of insertion, and use of the appropriate tools, we suggest that percutaneous anterior occiput-to-axis fixation technique is a feasible, safe, and minimally invasive procedure.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Anterior screw fixation; Cervical fixation; Minimally invasive; Occipitocervical fusion; Percutaneous

Mesh:

Year:  2013        PMID: 23932822     DOI: 10.1016/j.spinee.2013.05.056

Source DB:  PubMed          Journal:  Spine J        ISSN: 1529-9430            Impact factor:   4.166


  2 in total

1.  The radiological feature of anterior occiput-to-axis screw fixation as it guides the screw trajectory on 3D printed models: a feasibility study on 3D images and 3D printed models.

Authors:  Ai-Min Wu; Sheng Wang; Wan-Qing Weng; Zhen-Xuan Shao; Xin-Dong Yang; Jian-Shun Wang; Hua-Zi Xu; Yong-Long Chi
Journal:  Medicine (Baltimore)       Date:  2014-12       Impact factor: 1.889

2.  A novel computed method to reconstruct the bilateral digital interarticular channel of atlas and its use on the anterior upper cervical screw fixation.

Authors:  Ai-Min Wu; Wenhai Wang; Hui Xu; Zhong-Ke Lin; Xin-Dong Yang; Xiang-Yang Wang; Hua-Zi Xu; Yong-Long Chi
Journal:  PeerJ       Date:  2016-02-23       Impact factor: 2.984

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.