Screening for glaucoma using GDx-VCC in a population with ≥1 risk factors.

Gisèle Li1, Alvine Kamdeu Fansi, Paul Harasymowycz.   

Abstract

OBJECTIVE: To estimate the diagnostic accuracy of the GDx-VCC for glaucoma screening in a population with ≥1 risk factors for glaucoma.
DESIGN: Cross-sectional evaluation of a diagnostic test for screening. PARTICIPANTS: Two hundred forty-seven community-based volunteer participants with risk factors for glaucoma.
METHODS: The peripapillary retinal nerve fibre layers (RNFL) of participants' eyes were scanned using the GDx-VCC. Based on an ophthalmologic examination and frequency doubling perimetry, eyes were classified into 4 categories: normal, possible glaucoma, probable glaucoma, and definitive glaucoma. The sensitivities, specificities, positive and negative predictive values, and positive and negative likelihood ratios of the RNFL parameters were calculated.
RESULTS: The right eyes were retained for analyses. After excluding 5 eyes because of missing data and 23 eyes because of poor scan quality, the data of 219 right eyes were analyzed. Four eyes had definitive glaucoma. The best performing parameter was the nerve fibre indicator using a cutoff of 35 with a sensitivity of 75% (95% CI 19.4-99.4) at a specificity of 95% (95% CI 91.3-97.3), a positive predictive value of 25 (95% CI 4.3-48.1), a negative predictive value of 99 (95% CI 97.5-100.0), a positive likelihood ratio of 16 (95% CI 6.69-32.5), and a negative likelihood ratio of 0.20 (95% CI 0.05-1.44).
CONCLUSIONS: The GDx-VCC has inadequate sensitivity for screening of definitive glaucoma.
Copyright © 2013 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23931467     DOI: 10.1016/j.jcjo.2013.03.012

Source DB:  PubMed          Journal:  Can J Ophthalmol        ISSN: 0008-4182            Impact factor:   1.882


  3 in total

Review 1.  Optic nerve head and fibre layer imaging for diagnosing glaucoma.

Authors:  Manuele Michelessi; Ersilia Lucenteforte; Francesco Oddone; Miriam Brazzelli; Mariacristina Parravano; Sara Franchi; Sueko M Ng; Gianni Virgili
Journal:  Cochrane Database Syst Rev       Date:  2015-11-30

2.  Scanning laser polarimetry in glaucoma.

Authors:  Tanuj Dada; Reetika Sharma; Dewang Angmo; Gautam Sinha; Shibal Bhartiya; Sanjay K Mishra; Anita Panda; Ramanjit Sihota
Journal:  Indian J Ophthalmol       Date:  2014-11       Impact factor: 1.848

3.  Cost and detection rate of glaucoma screening with imaging devices in a primary care center.

Authors:  Alfonso Anton; Monica Fallon; Francesc Cots; María A Sebastian; Antonio Morilla-Grasa; Sergi Mojal; Xavier Castells
Journal:  Clin Ophthalmol       Date:  2017-02-16
  3 in total