Literature DB >> 23928093

Lanthanide-labeled immunochromatographic strips for the rapid detection of Pantoea stewartii subsp. stewartii.

Fan Zhang1, Mingqiang Zou, Yan Chen, Jinfeng Li, Yanfei Wang, Xiaohua Qi, Qiang Xue.   

Abstract

The lateral flow immunoassay is used in commercial pregnancy detection, and is an accepted point-of-care testing technique. The most widely used format for lateral flow immunochromatographic strips uses gold nanoparticles for colorimetric detection. However, this method often suffers from poor quantitative discrimination and low analytical sensitivity. To address these limitations, lanthanide chelate-loaded silica nanoparticles have been used as fluorescent labels. The fluorescent nanoparticles can easily bind to antibodies, with dextran as a linker. The strip reader described here was based on a sandwich immunoreaction performed on a strip, using lanthanide-labeled antibodies that served as signal vehicles for the fluorescent readout. The strip reader was used as a quantitative test system. In this work, Pantoea stewartii subsp. stewartii (Pss) was used as a model analyte to demonstrate the use of the strip reader. Under optimal conditions, the detection limit was determined as 10(3)cfu/mL. The quantification limit was calculated to be 10(4)cfu/mL. The detection limit for Pss was 100 times lower than those displayed by colloidal gold-labeled strips or ELISAs. No cross-reactions were observed with the other nine strains, indicating the good specificity of the Pss strip. This strip showed good stability in repeated tests. The tests using the fluorescence immunochromatographic strip were easy to perform, rapid, and sensitive. Methods using fluorescence strips and a strip reader have the potential to be a powerful tool for the quantification of bacteria.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Fluorescence strip; Pantoea stewartii subsp. stewartii; Rapid detection; Strip reader

Mesh:

Substances:

Year:  2013        PMID: 23928093     DOI: 10.1016/j.bios.2013.06.065

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  11 in total

1.  A Fluorescence Immunochromatographic Assay Using Europium (III) Chelate Microparticles for Rapid, Quantitative and Sensitive Detection of Creatine Kinase MB.

Authors:  Xiao-Hong Lai; Rong-Liang Liang; Tian-Cai Liu; Zhi-Ning Dong; Ying-Song Wu; Lin-Hai Li
Journal:  J Fluoresc       Date:  2016-04-01       Impact factor: 2.217

2.  Development of an immunochromatographic strip for rapid detection of Pantoea stewartii subsp. stewartii.

Authors:  Min Feng; Dezhao Kong; Wenbing Wang; Liqiang Liu; Shanshan Song; Chuanlai Xu
Journal:  Sensors (Basel)       Date:  2015-02-12       Impact factor: 3.576

3.  Rapid and Sensitive Lateral Flow Immunoassay Method for Procalcitonin (PCT) Based on Time-Resolved Immunochromatography.

Authors:  Xiang-Yang Shao; Cong-Rong Wang; Chun-Mei Xie; Xian-Guo Wang; Rong-Liang Liang; Wei-Wen Xu
Journal:  Sensors (Basel)       Date:  2017-02-28       Impact factor: 3.576

Review 4.  Time-Resolved Fluorescence Immunochromatography Assay (TRFICA) for Aflatoxin: Aiming at Increasing Strip Method Sensitivity.

Authors:  Hui Li; Du Wang; Xiaoqian Tang; Wen Zhang; Qi Zhang; Peiwu Li
Journal:  Front Microbiol       Date:  2020-05-06       Impact factor: 5.640

5.  Development of a europium nanoparticles lateral flow immunoassay for NGAL detection in urine and diagnosis of acute kidney injury.

Authors:  Moli Yin; Yuanwang Nie; Hao Liu; Lei Liu; Lu Tang; Yuan Dong; Chuanmin Hu; Huiyan Wang
Journal:  BMC Nephrol       Date:  2022-01-14       Impact factor: 2.388

Review 6.  Biosensor Technologies for Early Detection and Quantification of Plant Pathogens.

Authors:  Kazbek Dyussembayev; Prabhakaran Sambasivam; Ido Bar; Jeremy C Brownlie; Muhammad J A Shiddiky; Rebecca Ford
Journal:  Front Chem       Date:  2021-06-02       Impact factor: 5.221

7.  Evaluation of a smartphone-based rapid fluorescent diagnostic system for H9N2 virus in specific-pathogen-free chickens.

Authors:  Seon-Ju Yeo; Bui Thi Cuc; Haan Woo Sung; Hyun Park
Journal:  Arch Virol       Date:  2016-06-10       Impact factor: 2.574

8.  Europium (III) chelate microparticle-based lateral flow immunoassay strips for rapid and quantitative detection of antibody to hepatitis B core antigen.

Authors:  Rong-Liang Liang; Qiao-Ting Deng; Zhen-Hua Chen; Xu-Ping Xu; Jian-Wei Zhou; Jun-Yu Liang; Zhi-Ning Dong; Tian-Cai Liu; Ying-Song Wu
Journal:  Sci Rep       Date:  2017-10-26       Impact factor: 4.379

9.  Development of a rapid and sensitive europium (III) chelate microparticle-based lateral flow test strip for the detection and epidemiological surveillance of porcine epidemic diarrhea virus.

Authors:  Jianbo Liu; Hongyan Shi; Guangyi Cong; Jianfei Chen; Xin Zhang; Da Shi; Liyan Cao; Xiaobo Wang; Jialin Zhang; Zhaoyang Ji; Zhaoyang Jing; Li Feng
Journal:  Arch Virol       Date:  2020-03-06       Impact factor: 2.574

10.  Fluorescent fullerene nanoparticle-based lateral flow immunochromatographic assay for rapid quantitative detection of C-reactive protein.

Authors:  Kyung Mi Park; Da Jung Chung; Mijin Choi; Taejoon Kang; Jinyoung Jeong
Journal:  Nano Converg       Date:  2019-11-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.