Literature DB >> 23925919

Multicenter experience of the newly designed covered metallic ureteral stent for malignant ureteral occlusion: comparison with double J stent insertion.

Hwan Hoon Chung1, Man Deuk Kim, Jong Yun Won, Je Hwan Won, Sung Bum Cho, Tae-Seok Seo, Sang Woo Park, Byung Chul Kang.   

Abstract

PURPOSE: This study was designed to evaluate the effectiveness of the newly designed covered metallic stent (CMS) for malignant ureteral obstruction by comparing with double J stent (DJS).
MATERIAL AND METHODS: CMSs were placed for malignant ureteral obstruction caused by various types of cancers for 42 ureters in 32 patients from 7 institutes. Retrospective data were collected for DJSs, which included 72 malignant ureteral occlusions in 56 patients from a single institute. Twenty-seven DJSs were placed percutaneously, and 45 DJSs were cystoscopically inserted. Technical failure of the CMS group was compared with that of the radiologically inserted DJS group. Primary patency of the CMS group was compared with assisted primary patency of the DJS group.
RESULTS: Technical failure of the CMS group is lower than that of the radiologically inserted DJS group: 0% (0/42) vs. 25.9% (7/27; p = 0.002), respectively. Primary patency of the CMS group is better than assisted primary patency of the DJS group (p = 0.012). Primary patency of the CMSs is 100, 94.5, 74.7, 70.3, 65.3, 65.3, and 65.3% at 1, 3, 6, 9, 12, 18, and 24 months, respectively. Assisted primary patency of the DJS is 78.6, 75.1, 59.1, 48.7, 38.7, and 37.8% at 1, 3, 6, 9, 12, and 18 months, respectively. No serious complications were noted in the CMS group. Migration of the metallic stent occurred in one patient (2.3%).
CONCLUSIONS: Covered metallic stent placement for malignant ureteral obstruction is superior to the double J stent placement in terms of technical success and patency.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23925919     DOI: 10.1007/s00270-013-0675-2

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  6 in total

1.  Comparison of single and tandem ureteral stenting for malignant ureteral obstruction: a prospective study of 104 patients.

Authors:  Kao-Lang Liu; Bo-Ching Lee; Jian-De Ye; Yu-Hsuan Chang; Chin-Chen Chang; Kuo-How Huang; Yuan-Ju Lee; Yeun-Chung Chang
Journal:  Eur Radiol       Date:  2018-07-04       Impact factor: 5.315

Review 2.  The effectiveness of ureteric metal stents in malignant ureteric obstructions: A systematic review.

Authors:  Panagiotis Kallidonis; Dimitrios Kotsiris; Francesco Sanguedolce; Panteleimon Ntasiotis; Evangelos Liatsikos; Athanasios Papatsoris
Journal:  Arab J Urol       Date:  2017-10-16

3.  Treatment outcomes of ureteral stenting for malignant extrinsic ureteral obstruction: a comparison between polymeric and metallic stents.

Authors:  Jumpei Asakawa; Taro Iguchi; Satoshi Tamada; Noriko Ninomiya; Minoru Kato; Takeshi Yamasaki; Tatsuya Nakatani
Journal:  Cancer Manag Res       Date:  2018-08-28       Impact factor: 3.989

4.  Fluoroscopy Guided Transurethral Placement of Ureteral Metallic Stents.

Authors:  Song Myung Gyu; Tae Seok Seo; Cheol Min Park; Jae Woong Choi; Jong Mee Lee; Yang Shin Park
Journal:  Iran J Radiol       Date:  2015-07-22       Impact factor: 0.212

Review 5.  Stents for malignant ureteral obstruction.

Authors:  Kristina Pavlovic; Dirk Lange; Ben H Chew
Journal:  Asian J Urol       Date:  2016-05-13

6.  A Prospective Randomized Comparison of a Covered Metallic Ureteral Stent and a Double-J Stent for Malignant Ureteral Obstruction.

Authors:  Jong Woo Kim; Bumsik Hong; Ji Hoon Shin; Jihong Park; Jin Hyoun Kim; Dong Il Gwon; Min-Hee Ryu; Baek-Yeol Ryoo
Journal:  Korean J Radiol       Date:  2018-06-14       Impact factor: 3.500

  6 in total