Literature DB >> 23920473

Reliability of a 2-bout exercise test on a wattbike cycle ergometer.

Matthew W Driller1, Christos K Argus, Jason C Bartram, Jacinta Boniventura, David T Martin, Nicholas P West, Shona L Halson.   

Abstract

PURPOSE: To determine the intraday and interday reliability of a 2 × 4-min performance test on a cycle ergometer (Wattbike) separated by 30 min of passive recovery (2 × 4MMP).
METHODS: Twelve highly trained cyclists (mean ± SD; age = 20 ± 2 y, predicted VO2max = 59.0 ± 3.6 mL · kg-1 · min-1) completed six 2 × 4MMP cycling tests on a Wattbike ergometer separated by 7 d. Mean power was measured to determine intraday (test 1 [T1] to test 2 [T2]) and interday reliability (weeks 1-6) over the repeated trials.
RESULTS: The mean intraday reliabilities of the 2 × 4MMP test, as expressed by the typical error of measurement (TEM, W) and coefficient of variation (CV, %) over the 6 wk, were 10.0 W (95% confidence limits [CL] 8.2-11.8), and 2.6% (95%CL 2.1-3.1), respectively. The mean interday reliability TEM and CV for T1 over the 6 wk were 10.4 W (95%CL 8.7-13.3) and 2.7% (95%CL 2.3-3.5), respectively, and 11.7 W (95%CL 9.8-15.1) and 3.0% (95%CL 2.5-3.9) for T2.
CONCLUSION: The testing protocol performed on a Wattbike cycle ergometer in the current study is reproducible in highly trained cyclists. The high intraday and interday reliability make it a reliable method for monitoring cycling performance and for investigating factors that affect performance in cycling events.

Entities:  

Mesh:

Year:  2013        PMID: 23920473     DOI: 10.1123/ijspp.2013-0103

Source DB:  PubMed          Journal:  Int J Sports Physiol Perform        ISSN: 1555-0265            Impact factor:   4.010


  3 in total

1.  Shorter constant work rate cycling tests as proxies for longer tests in highly trained cyclists.

Authors:  Chantelle du Plessis; Mark Andrews; Lachlan J G Mitchell; Jodie Cochrane Wilkie; Trish King; Anthony J Blazevich
Journal:  PLoS One       Date:  2022-05-23       Impact factor: 3.752

2.  Effects of a 3-month recreative exercise applied to individuals with intellectual disability on their electromyogram (EMG) variations and balance performance.

Authors:  Elif Top; Mustafa Akil
Journal:  Int J Dev Disabil       Date:  2017-04-21

3.  Validity of PowerTap P1 Pedals during Laboratory-Based Cycling Time Trial Performance.

Authors:  Chris Whittle; Neal Smith; Simon A Jobson
Journal:  Sports (Basel)       Date:  2018-09-05
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.