Literature DB >> 23916666

Transmission analysis of ultrasonic Lamb mode conversion in a plate with partial-thickness notch.

Kailiang Xu1, Dean Ta, Zhongqing Su, Weiqi Wang.   

Abstract

Mode conversions of Lamb waves can occur upon encountering damage or defect such as a notch, leading to newly-converted modes apart from wave reflection and transmission. In this paper, the transmission of the fundamental Lamb modes symmetrical S0 and anti-symmetrical A0 with anti-symmetrical notches were investigated in steel plates within the relatively short propagation distance. The group velocity and modal energy of the converted modes were analyzed using simulations and experiments. Two-dimensional finite difference time domain (2D-FDTD) method was employed to calculate the scattering field and extract numerical trends for simulation study and experimental confirmation. Both simulations and experiments revealed that the apparent group velocities of the converted modes in the transmitted signals subject to the notch positions. To describe the mode conversion degree and evaluate the notch severity, wave packets of the originally-transmitted modes and newly-converted modes were separated and corresponding mode energy percentages were analyzed at different notch severities. Frequency-sweeping measurements illustrated that the modal energy percentages varied monotonically over the notch-depth increase with a statistically consistency (R=1.00, P<0.0004).
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Group velocity; Mode conversion; Mode energy; Notches; Ultrasonic Lamb waves

Mesh:

Year:  2013        PMID: 23916666     DOI: 10.1016/j.ultras.2013.07.011

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  4 in total

1.  Axial transmission method for long bone fracture evaluation by ultrasonic guided waves: simulation, phantom and in vitro experiments.

Authors:  Kailiang Xu; Dean Ta; Runxin He; Yi-Xian Qin; Weiqi Wang
Journal:  Ultrasound Med Biol       Date:  2014-01-13       Impact factor: 2.998

2.  Basic study for ultrasound-based navigation for pedicle screw insertion using transmission and backscattered methods.

Authors:  Ziqiang Chen; Bing Wu; Xiao Zhai; Yushu Bai; Xiaodong Zhu; Beier Luo; Xiao Chen; Chao Li; Mingyuan Yang; Kailiang Xu; Chengcheng Liu; Chuanfeng Wang; Yingchuan Zhao; Xianzhao Wei; Kai Chen; Wu Yang; Dean Ta; Ming Li
Journal:  PLoS One       Date:  2015-04-10       Impact factor: 3.240

3.  Transverse and Oblique Long Bone Fracture Evaluation by Low Order Ultrasonic Guided Waves: A Simulation Study.

Authors:  Ying Li; Dan Liu; Kailiang Xu; Dean Ta; Lawrence H Le; Weiqi Wang
Journal:  Biomed Res Int       Date:  2017-01-15       Impact factor: 3.411

4.  A New Approach to Guided Wave Ray Tomography for Temperature-Robust Damage Detection Using Piezoelectric Sensors.

Authors:  Dan Li; Ming Shi; Feng Xu; Chengcheng Liu; Jianqiu Zhang; Dean Ta
Journal:  Sensors (Basel)       Date:  2018-10-18       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.