Literature DB >> 23916447

Determination of the force systems produced by different configurations of tear drop orthodontic loops.

Guilherme Thiesen1, Roberto Hideo Shimizu, Caio Vinicius Martins do Valle, Karyna Martins do Valle-Corotti, Jefferson Ricardo Pereira, Paulo Cesar Rodrigues Conti.   

Abstract

OBJECTIVE: To determine the mechanical characteristics of teardrop loop with and without helix fabricated using different metal alloy compositions (stainless steel and beta-titanium), submitted to different intensities of bends preactivation (0° and 40°), and with different cross-sectional dimension of the wire used to build these loops (0.017 x 0.025-in and 0.019 x 0.025-in).
METHODS: Eighty loops used to close spaces were submitted to mechanical tests. The magnitudes of horizontal force, the moment/force ratio, and the load/deflection ratio produced by the specimens were quantified. Loops were submitted to a total activation of 5.0 mm and the values were registered for each 1.0 mm of activation. For statistic data analysis, a analysis of variance was performed and a Tukey's Multiple Comparison test was used as supplement, considering a 5% level of significance.
RESULTS: In general, teardrop loops with helix produced lower magnitudes of horizontal force and load/deflection ratio, and higher moment/force ratio than teardrop loops without helix. Among all analyzed variables, metal alloy composition presented greater influence in the horizontal force and in the load/deflection ratio. The moment/force ratio showed to be more influenced by the preactivation of loops for space closure.

Entities:  

Keywords:  Biomechanics; Orthodontic space closure; Orthodontics; Tooth extraction

Mesh:

Substances:

Year:  2013        PMID: 23916447     DOI: 10.1590/s2176-94512013000200007

Source DB:  PubMed          Journal:  Dental Press J Orthod        ISSN: 2176-9451


  4 in total

1.  Understanding the basis of space closure in Orthodontics for a more efficient orthodontic treatment.

Authors:  Gerson Luiz Ulema Ribeiro; Helder B Jacob
Journal:  Dental Press J Orthod       Date:  2016 Mar-Apr

2.  Mechanical force system of double key loop with finite element analysis.

Authors:  Jiali Liu; Duanqiang Zhang; Linyu Xu; Senxin Cai; Jinquan Guo; Jiang Chen; Jiehua Su
Journal:  BMC Oral Health       Date:  2021-06-13       Impact factor: 2.757

3.  Effect of activation and preactivation on the mechanical behavior and neutral position of stainless steel and beta-titanium T-loops.

Authors:  Saúl Matos de Castro; Rui Moreira; Ana Cristina Braga; Afonso Pinhão Ferreira; Maria Cristina Pollmann
Journal:  Korean J Orthod       Date:  2015-07-24       Impact factor: 1.372

4.  Class I malocclusion with severe double protrusion treated with first premolars extraction.

Authors:  Ricardo Moresca
Journal:  Dental Press J Orthod       Date:  2014 May-Jun
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.