Literature DB >> 23916114

Non-contact laser-scanning confocal microscopy of the human cornea in vivo.

Nicola Pritchard1, Katie Edwards1, Nathan Efron2.   

Abstract

PURPOSE: To investigate the utility of using non-contact laser-scanning confocal microscopy (NC-LSCM), compared with the more conventional contact laser-scanning confocal microscopy (C-LSCM), for examining corneal substructures in vivo.
METHODS: An attempt was made to capture representative images from the tear film and all layers of the cornea of a healthy, 35 year old female, using both NC-LSCM and C-LSCM, on separate days.
RESULTS: Using NC-LSCM, good quality images were obtained of the tear film, stroma, and a section of endothelium, but the corneal depth of the images of these various substructures could not be ascertained. Using C-LSCM, good quality, full-field images were obtained of the epithelium, subbasal nerve plexus, stroma, and endothelium, and the corneal depth of each of the captured images could be ascertained.
CONCLUSIONS: NC-LSCM may find general use for clinical examination of the tear film, stroma and endothelium, with the caveat that the depth of stromal images cannot be determined when using this technique. This technique also facilitates image capture of oblique sections of multiple corneal layers. The inability to clearly and consistently image thin corneal substructures - such as the tear film, subbasal nerve plexus and endothelium - is a key limitation of NC-LSCM.
Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Cornea; Non-contact laser scanning confocal microscopy; Tear film

Mesh:

Year:  2013        PMID: 23916114     DOI: 10.1016/j.clae.2013.07.002

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  3 in total

1.  Assessing microstructures of the cornea with Gabor-domain optical coherence microscopy: pathway for corneal physiology and diseases.

Authors:  Patrice Tankam; Zhiguo He; Ying-Ju Chu; Jungeun Won; Cristina Canavesi; Thierry Lepine; Holly B Hindman; David J Topham; Philippe Gain; Gilles Thuret; Jannick P Rolland
Journal:  Opt Lett       Date:  2015-03-15       Impact factor: 3.776

2.  Hybrid Robot-assisted Frameworks for Endomicroscopy Scanning in Retinal Surgeries.

Authors:  Zhaoshuo Li; Mahya Shahbazi; Niravkumar Patel; Eimear O' Sullivan; Haojie Zhang; Khushi Vyas; Preetham Chalasani; Anton Deguet; Peter L Gehlbach; Iulian Iordachita; Guang-Zhong Yang; Russell H Taylor
Journal:  IEEE Trans Med Robot Bionics       Date:  2020-04-16

3.  Corneal Confocal Microscopy and the Nervous System: Introduction to the Special Issue.

Authors:  Rayaz A Malik; Nathan Efron
Journal:  J Clin Med       Date:  2022-03-08       Impact factor: 4.241

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.