Literature DB >> 23915578

In-vitro investigation of a potential wave pumping effect in human aorta.

Niema M Pahlevan1, Morteza Gharib.   

Abstract

An impedance pump - also known as Liebau pump - is a simple valveless pump that operates based on the principles of wave propagation and reflection. It has been shown in embryonic zebrafish that a similar mechanism is responsible for the pumping action in the embryonic heart during the early stages before valve formation. Recent studies suggest that the cardiovascular system is designed to take advantage of wave propagation and reflection phenomena in the arterial network. In this study we report the results of an in-vitro study that examines the hypothesis that the adult human aorta acts as a passive pump based on Liebau effect. A hydraulic model with different compliant models of an artificial aorta was used for a series of in-vitro experiments. Our result indicates that wave propagation and reflection can result in a pumping mechanism in a compliant aorta.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Aortic waves; Arterial wave reflection; Impedance pump; Left ventricular workload; Liebau effect

Mesh:

Year:  2013        PMID: 23915578     DOI: 10.1016/j.jbiomech.2013.07.006

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  6 in total

1.  Model-Based Fluid-Structure Interaction Approach for Evaluation of Thoracic Endovascular Aortic Repair Endograft Length in Type B Aortic Dissection.

Authors:  Arian Aghilinejad; Heng Wei; Gregory A Magee; Niema M Pahlevan
Journal:  Front Bioeng Biotechnol       Date:  2022-06-23

2.  On the convergence and accuracy of the cardiovascular intrinsic frequency method.

Authors:  Peyman Tavallali; Thomas Y Hou; Derek G Rinderknecht; Niema M Pahlevan
Journal:  R Soc Open Sci       Date:  2015-12-16       Impact factor: 2.963

3.  Kinking and Torsion Can Significantly Improve the Efficiency of Valveless Pumping in Periodically Compressed Tubular Conduits. Implications for Understanding of the Form-Function Relationship of Embryonic Heart Tubes.

Authors:  Florian Hiermeier; Jörg Männer
Journal:  J Cardiovasc Dev Dis       Date:  2017-11-19

4.  Impedance Pumping and Resonance in a Multi-Vessel System.

Authors:  Victor Zislin; Moshe Rosenfeld
Journal:  Bioengineering (Basel)       Date:  2018-08-09

Review 5.  Building Valveless Impedance Pumps From Biological Components: Progress and Challenges.

Authors:  Narine Sarvazyan
Journal:  Front Physiol       Date:  2022-01-31       Impact factor: 4.566

6.  Proof-of-concept for a non-invasive, portable, and wireless device for cardiovascular monitoring in pediatric patients.

Authors:  Jennifer C Miller; Jennifer Shepherd; Derek Rinderknecht; Andrew L Cheng; Niema M Pahlevan
Journal:  PLoS One       Date:  2020-01-03       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.