Complications with computer-aided designed/computer-assisted manufactured titanium and soldered gold bars for mandibular implant-overdentures: short-term observations.

Joannis Katsoulis1, Julia Wälchli, Simone Kobel, Hadi Gholami, Regina Mericske-Stern.   

Abstract

BACKGROUND: Implant-overdentures supported by rigid bars provide stability in the edentulous atrophic mandible. However, fractures of solder joints and matrices, and loosening of screws and matrices were observed with soldered gold bars (G-bars). Computer-aided designed/computer-assisted manufactured (CAD/CAM) titanium bars (Ti-bars) may reduce technical complications due to enhanced material quality.
PURPOSE: To compare prosthetic-technical maintenance service of mandibular implant-overdentures supported by CAD/CAM Ti-bar and soldered G-bar.
MATERIALS AND METHODS: Edentulous patients were consecutively admitted for implant-prosthodontic treatment with a maxillary complete denture and a mandibular implant-overdenture connected to a rigid G-bar or Ti-bar. Maintenance service and problems with the implant-retention device complex and the prosthesis were recorded during minimally 3-4 years. Annual peri-implant crestal bone level changes (ΔBIC) were radiographically assessed.
RESULTS: Data of 213 edentulous patients (mean age 68 ± 10 years), who had received a total of 477 tapered implants, were available. Ti-bar and G-bar comprised 101 and 112 patients with 231 and 246 implants, respectively. Ti-bar mostly exhibited distal bar extensions (96%) compared to 34% of G-bar (p < .001). Fracture rate of bars extensions (4.7% vs 14.8%, p < .001) and matrices (1% vs 13%, p < .001) was lower for Ti-bar. Matrices activation was required 2.4× less often in Ti-bar. ΔBIC remained stable for both groups.
CONCLUSIONS: Implant overdentures supported by soldered gold bars or milled CAD/CAM Ti-bars are a successful treatment modality but require regular maintenance service. These short-term observations support the hypothesis that CAD/CAM Ti-bars reduce technical complications. Fracture location indicated that the titanium thickness around the screw-access hole should be increased.
© 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  CAD/CAM technology; complications; gold; implant-overdenture; maintenance service; rigid bar; titanium

Mesh:

Substances:

Year:  2013        PMID: 23915228     DOI: 10.1111/cid.12130

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  2 in total

1.  [Clinical application of mandibular overdenture supported by a two-implant and interforaminal bar in an edentulous atrophic mandible].

Authors:  Dao Li; Xiao Xue; Wang Xiaodong; Zhao Ke
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2017-08-01

2.  Fabrication of a customized impression metal jig for an implant-supported overdenture with a milled bar.

Authors:  Yeganeh Memari; Azadeh Tadayonfard; Amir Fayaz; Elaheh Beyabanaki
Journal:  Dent Res J (Isfahan)       Date:  2021-04-06
  2 in total