Literature DB >> 23914856

Distal false lumen occlusion in aortic dissection with a homemade extra-large vascular plug: the candy-plug technique.

Tilo Kölbel1, Christina Lohrenz, Arne Kieback, Holger Diener, Eike Sebastian Debus, Axel Larena-Avellaneda.   

Abstract

PURPOSE: To report a technique to create an extra-large vascular plug for occlusion of a large distal false lumen in chronic aortic dissection. TECHNIQUE: The "candy-plug" technique is demonstrated in a 58-year-old multimorbid man with a history of complicated acute type B aortic dissection and a 9-cm chronic thoracic false lumen aneurysm. The patient underwent a staged repair with a cervical debranching procedure as a first step and a thoracic endovascular aortic repair from the innominate artery to the celiac artery as a second step. To occlude the large false lumen from a distal route, a stent-graft was modified on-table with a diameter-restricting suture, giving it a wrapped candy-like shape. This plug was deployed into the false lumen, and the remaining opening was occluded with a standard vascular plug. On 3-month follow-up imaging, the thoracic false lumen aneurysm remained completely thrombosed.
CONCLUSION: The candy-plug technique can facilitate complete occlusion of chronic thoracic false lumen aneurysm by prohibiting distal false lumen backflow.

Entities:  

Mesh:

Year:  2013        PMID: 23914856     DOI: 10.1583/13-4318.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  15 in total

Review 1.  Treatment of uncomplicated type B aortic dissection.

Authors:  Hitoshi Matsuda
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-12-05

2.  Radical treatment of primary type B aortic dissection or after thoracic endovascular aortic repair to manage disseminated intravascular coagulation.

Authors:  Lixin Wang; Fei Liu; Daqiao Guo; Demin Xu; Xiushi Zhou; Kai Hou; Wei Zhang; Zhenyu Shi; Xiao Tang; Weiguo Fu
Journal:  J Thorac Dis       Date:  2018-06       Impact factor: 2.895

Review 3.  Complicated acute type B aortic dissection: update on management and results.

Authors:  Eric Y Pruitt; Salvatore T Scali; Dean J Arnaoutakis; Martin R Back; George J Arnaoutakis; Tomas D Martin; Thomas M Beaver; Thomas S Huber; Gilbert R Upchurch
Journal:  J Cardiovasc Surg (Torino)       Date:  2020-09-23       Impact factor: 1.888

4.  Modified 'candy-plug' technique for chronic type B aortic dissection with aneurysmal dilatation: a case report.

Authors:  Sohsyu Kotani; Yoshito Inoue; Mio Kasai; Satoru Suzuki; Takashi Hachiya
Journal:  J Cardiothorac Surg       Date:  2017-09-05       Impact factor: 1.637

5.  Thoracic endovascular aortic repair with true-false-true lumen deployment.

Authors:  Neel A Mansukhani; Matthew C Chia; Gabriel A Wallace; Andrew W Hoel; Mark K Eskandari
Journal:  J Vasc Surg Cases Innov Tech       Date:  2020-05-28

6.  Embolization of the false lumen using IMPEDE-FX embolization plugs as part of treatment of an infrarenal post-dissection aneurysm: a case report.

Authors:  Anne-Jet S Jansen; Paul M van Schaik; Jasper M Martens; Michel M P J Reijnen
Journal:  CVIR Endovasc       Date:  2020-12-04

7.  Targeting fenestrations in an aortic aneurysm secondary to chronic type A or B dissections: a case series.

Authors:  Chen Speter; Daniel Silverberg; Tal Segev; Halak Moshe
Journal:  J Vasc Surg Cases Innov Tech       Date:  2021-06-04

8.  False Lumen Embolization with the Candy Plug Technique for Consumptive Coagulopathy after Aortic Repair for Chronic Dissection.

Authors:  Shota Hasegawa; Yoshikatsu Nomura; Hirohisa Murakami
Journal:  EJVES Short Rep       Date:  2019-08-21

9.  False lumen embolization as a rescue technique in the setting of acute and chronic dissecting aneurysms as adjunct to thoracic endovascular aortic repair.

Authors:  Stephanie Rakestraw; Anthony Feghali; Kevin Nguyen; Dawn Salvatore; Paul DiMuzio; Babak Abai
Journal:  J Vasc Surg Cases Innov Tech       Date:  2020-02-20

Review 10.  Endovascular strategies for post-dissection aortic aneurysm (PDAA).

Authors:  Zhaoxiang Zeng; Yuxi Zhao; Mingwei Wu; Xianhao Bao; Tao Li; Jiaxuan Feng; Rui Feng; Zaiping Jing
Journal:  J Cardiothorac Surg       Date:  2020-10-01       Impact factor: 1.637

View more