Literature DB >> 23914739

Use of an ex vivo canine ventral slot model to test the efficacy of a piezoelectric cutting tool for decompressive spinal surgery.

Michael Farrell1, Miguel A Solano, Noel Fitzpatrick, Jelena Jovanovik.   

Abstract

OBJECTIVE: To test the efficacy of a piezoelectric instrument (PI) for bone removal during ventral slot surgery. STUDY
DESIGN: Ex vivo feasibility study. SAMPLE POPULATION: Cadaveric canine cervical spinal specimens (n = 3; C1-7; C1-T1; C2-T1).
METHODS: The spinal cord of each explanted spinal unit was replaced with a saline-filled latex condom. In 8 disc spaces, ventral slot surgery was performed using a previously reported technique. Bone removal was achieved using a motorized burr (MB). In 8 disc spaces, bone was removed via en bloc ostectomy with a PI that selectively cuts mineralized tissue. Surgical duration and operating field visibility were recorded. Rupture of the fluid filled condom was used as a measure of iatrogenic collateral trauma. Computed tomography was used to measure ventral slot morphometry.
RESULTS: Mean surgical duration for PI (23.4 minutes) was significantly shorter than for MB (34.1 minutes; P = .049). Using a 4 point Likert scale (4 = excellent, 3 = good, 2 = fair, 1 = poor), median visibility score was significantly higher for PI (2) than for MB (1; P = .03). The condom burst twice (1MB, 1PI) during elevation of the dorsal longitudinal ligament; there was no significant difference between techniques for incidence of collateral trauma (P = .99). Regardless of surgical technique, there was a bias in slot deviation towards the right (i.e., the surgeon's left; P = .021).
CONCLUSIONS: The PI allowed completion of ventral slots in a significantly shorter time, without an increased incidence of iatrogenic trauma. The right-handed surgeon showed a left-sided aiming bias, regardless of surgical technique. © Copyright 2013 by The American College of Veterinary Surgeons.

Entities:  

Mesh:

Year:  2013        PMID: 23914739     DOI: 10.1111/j.1532-950X.2013.12051.x

Source DB:  PubMed          Journal:  Vet Surg        ISSN: 0161-3499            Impact factor:   1.495


  2 in total

1.  Evaluation of the Iatrogenic Sciatic Nerve Injury following Double Pelvic Osteotomy Performed with Piezoelectric Cutting Tool in Dogs.

Authors:  Roberto Properzi; Francesco Collivignarelli; Andrea Paolini; Amanda Bianchi; Massimo Vignoli; Ilaria Falerno; Andrea De Bonis; Roberto Tamburro
Journal:  Vet Sci       Date:  2022-05-29

Review 2.  Piezoelectric Bone Surgery: A Review of the Literature and Potential Applications in Veterinary Oromaxillofacial Surgery.

Authors:  Philippe Hennet
Journal:  Front Vet Sci       Date:  2015-05-05
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.