Literature DB >> 2390732

Linear calibration of radiographic mineral density using video-digitizing methods.

R B Martin1, T Papamichos, G A Dannucci.   

Abstract

Radiographic images can provide quantitative as well as qualitative information if they are subjected to densitometric analysis. Using modern video-digitizing techniques, such densitometry can be readily accomplished using relatively inexpensive computer systems. However, such analyses are made more difficult by the fact that the density values read from the radiography have a complex, nonlinear relationship to bone mineral content. This article derives the relationship between these variables from the nature of the intermediate physical processes, and presents a simple mathematical method for obtaining a linear calibration function using a step wedge or other standard.

Mesh:

Year:  1990        PMID: 2390732     DOI: 10.1007/bf02555991

Source DB:  PubMed          Journal:  Calcif Tissue Int        ISSN: 0171-967X            Impact factor:   4.333


  13 in total

1.  Microscopic metabolism of calcium in bone. III. Microradiographic measurements of mineral density.

Authors:  R E ROWLAND; J JOWSEY; J H MARSHALL
Journal:  Radiat Res       Date:  1959-02       Impact factor: 2.841

2.  Biophysical investigations of the mineral phase in healing fractures.

Authors:  U NILSONNE
Journal:  Acta Orthop Scand Suppl       Date:  1959

3.  Biophysical analyses of the formation and structure of human fetal bone; a microradiographic and x-ray crystallographic study.

Authors:  G WALLGREN
Journal:  Acta Paediatr Suppl       Date:  1957-07

4.  Procedures and errors in quantitative historadiography.

Authors:  J J CLEMMONS
Journal:  Biochim Biophys Acta       Date:  1955-07

5.  Studies on x ray absorption and diffraction of bone tissue.

Authors:  R AMPRINO; A ENGSTROM
Journal:  Acta Anat (Basel)       Date:  1952

6.  Bone mass determination from microradiographs by computer-assisted videodensitometry. I. Methodology.

Authors:  K G Strid; P Kälebo
Journal:  Acta Radiol       Date:  1988 Jul-Aug       Impact factor: 1.990

7.  A television scanning system for the measurement of the spatial variation of micro-density in bone sections.

Authors:  C M McQueen; D A Smith; I B Monk; P W Horton
Journal:  Calcif Tissue Res       Date:  1973-02-19

8.  Digital processing of microradiographic and fluorochromic images from bone biopsy.

Authors:  H K Huang; G L Meyers; R K Martin; J P Albright
Journal:  Comput Biol Med       Date:  1983       Impact factor: 4.589

9.  Quantitative analysis of x-ray images with a television image analyser.

Authors:  A Schleicher; B Tillmann; K Zilles
Journal:  Microsc Acta       Date:  1980-07

10.  Computer-assisted video analysis of [3H]spiroperidol binding autoradiographs.

Authors:  C A Altar; R J Walter; K A Neve; J F Marshall
Journal:  J Neurosci Methods       Date:  1984-03       Impact factor: 2.390

View more
  2 in total

1.  Videodensitometry of osteons in females with femoral neck fractures.

Authors:  R G Squillante; J L Williams
Journal:  Calcif Tissue Int       Date:  1993-04       Impact factor: 4.333

2.  Remineralization of demineralized bone matrix (DBM) via alternating solution immersion (ASI).

Authors:  Matthew A Soicher; Blaine A Christiansen; Susan M Stover; J Kent Leach; David P Fyhrie
Journal:  J Mech Behav Biomed Mater       Date:  2013-05-22
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.