Literature DB >> 23906703

Is radiographic measurement of distal femoral torsion reliable?

T Viel1, C Casin, F Ducellier, V Steiger, N Bigorre, P Bizot.   

Abstract

BACKGROUND: Distal femur torsion (DFT) is a crucial parameter in knee replacement surgery. The reference standard for measuring DFT is posterior condylar angle (PCA) measurement using computed tomography (CT). The objective of this study was to assess the feasibility and reliability of a radiographic PCA measurement method.
MATERIALS AND METHODS: We studied 125 osteoarthritic knees in 79 patients (42 women and 37 men) with a mean age of 71.6 ± 8.8 years (range 47 to 86 years); 32 knees were aligned, 85 in varus, and eight in valgus. DFT was measured on an antero-posterior (AP) radiograph of the knee in 90° of flexion (known as the seated AP view). The PCA was defined as the angle subtended by the tangent to the posterior condyles and the transepicondylar axis (anatomic PCA [aPCA]) or the line connecting the lateral epicondyle to the medial sulcus (surgical PCA [sPCA]). The PCA was conventionally recorded as positive in the event of external torsion and negative in the event of internal torsion. PCA measurements were performed three times by each of five observers to allow assessments of inter-observer and test-retest reliabilities.
RESULTS: aPCA was consistently negative (mean, -6.1 ± 1.6°) (range, 0 to -10°); inter-observer and test-retest reliability were satisfactory (0.54<rw 0.80). sPCA was positive in 41 knees and negative in 84 knees) (mean, -0.3 ± 1.4°) (range, -5° to +2°); inter-observer and test-retest reliabilities were poor (0.28<r<0.69). A weak but significant correlation was found between aPCA and coronal alignment, with a trend towards greater internal torsion in the group of valgus knees.
CONCLUSION: Radiographic measurement of DFT is simple and non-invasive. Measurement reproducibility was satisfactory for aPCA but not for sPCA. aPCA showed marked inter-individual variability and tended to increase when the knee was in valgus. Mean aPCA values were comparable to those reported using CT. In contrast to CT, radiographic DFT measurement can easily be incorporated into the pre- and postoperative work-ups for knee replacement surgery, provided the patient can achieve 90° of knee flexion. LEVEL OF EVIDENCE: Level IV, prospective cohort study.
Copyright © 2013. Published by Elsevier Masson SAS.

Entities:  

Keywords:  Conventional radiography; Distal femoral torsion; Posterior condylar angle; Seated radiography; Total knee arthroplasty; Transepicondylar axis

Mesh:

Year:  2013        PMID: 23906703     DOI: 10.1016/j.otsr.2013.02.009

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  5 in total

1.  Intra- and postoperative assessment of femoral component rotation in total knee arthroplasty: an EKA knee expert group clinical review.

Authors:  Paweł Skowronek; Markus Arnold; Christian Starke; Agnieszka Bartyzel; Lukas B Moser; Michael T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-04-30       Impact factor: 4.342

2.  Partially loaded plain radiographic measurement to evaluate rotational alignment in total knee arthroplasty.

Authors:  William Pedraza; Johannes Beckmann; Constantin Mayer; Frieder Mauch; Jochen Huth; Raymond Best
Journal:  Int Orthop       Date:  2016-07-22       Impact factor: 3.075

3.  Pre-operative radiological measurement of femoral rotation for prosthetic positioning in total knee arthroplasty.

Authors:  Liliana Savin; Paul Botez; Dan Mihailescu; Vlad Predescu; Carmen Grierosu
Journal:  Int Orthop       Date:  2016-01-23       Impact factor: 3.075

4.  Evaluating distal femoral torsion and posterior condylar line reliability for adjusting femoral component rotation in TKA, Egyptian population radiographic study.

Authors:  Mohamed A Mahran; Ahmed A Khalifa; Moataz Abdelraheem Ahmed; Hatem M Bakr; Yaser E Khalifa
Journal:  J Clin Orthop Trauma       Date:  2020-12-05

Review 5.  A Protocol to Systematic Radiographic Assessment of Primary Total Knee Arthroplasty.

Authors:  Ahmed A Khalifa; Arun B Mullaji; Alaa M Mostafa; Osama A Farouk
Journal:  Orthop Res Rev       Date:  2021-07-17