Abstract
The aim of this study was to establish a method of purifying intact complement factor H (CFH) from human plasma. CFH was isolated from human plasma by polyethylene glycol (PEG) precipitation, following three sequential chromatographic columns, which consisted of l-lysine Sepharose column, Resource Q column and Sephacryl S-300 High Resolution HiPrep 16/60 column. All the above steps were performed at 4°C by Fast Protein Liquid Chromatography (FPLC) AKTA Purifier 10 with Frac-900. Identification of the purified CFH was confirmed by SDS-PAGE and Western blot. The following functions of the purified CFH were further analyzed compared with the commercial CFH in vitro: (1) binding ability with C3b; (2) binding ability with mCRP; (3) the protecting function of the hemolysis of sheep red blood cells; (4) the cofactor role for complement factor I-mediated proteolytic inactivation of C3b. Homogeneous CFH was purified from the plasma fraction through the above four steps. The purity and the functions of the purified CFH were comparable to the commercial CFH. The yield of CFH was 26±3% in our study. Compared with previous methods, our method was high yield with high purity. We established a stable and feasible system for purifying intact CFH, which could be used in the lab and clinical investigations.Entities:
Keywords: Chromatography; Complement factor H; Human plasma; Purification
Mesh:
Substances:
Year: 2013 PMID: 23906520 DOI: 10.1016/j.pep.2013.07.014