Literature DB >> 23906317

The effect of metal microstructure on the initial attachment of Escherichia coli to 1010 carbon steel.

M A Javed1, P R Stoddart, S L McArthur, S A Wade.   

Abstract

Metallurgical features have been shown to play an important role in the attachment of microorganisms to metal surfaces. In the present study, the influence of the microstructure of as-received (AR) and heat-treated (HT) 1010 carbon steel on the initial attachment of bacteria was investigated. Heat treatment was carried out with the aim of increasing the grain size of the carbon steel coupons. Mirror-polished carbon steel coupons were immersed in a minimal medium inoculated with Escherichia coli (ATCC 25922) to investigate the early (15, 30 and 60 min) and relatively longer-term (4 h) stages of bacterial attachment. The results showed preferential colonisation of bacteria on the grain boundaries of the steel coupons. The bacterial attachment to AR steel coupons was relatively uniform compared to the HT steel coupons where an increased number of localised aggregates of bacteria were found. Quantitative analysis showed that the ratio of the total number of isolated (i.e., single) bacteria to the number of bacteria in aggregates was significantly higher on the AR coupons than the HT coupons. Longer-term immersion studies showed production of extracellular polymeric substances by the bacteria and corrosion at the grain boundaries on both types of steel coupon tested.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23906317     DOI: 10.1080/08927014.2013.820826

Source DB:  PubMed          Journal:  Biofouling        ISSN: 0892-7014            Impact factor:   3.209


  3 in total

1.  Flow Chamber System for the Statistical Evaluation of Bacterial Colonization on Materials.

Authors:  Friederike Menzel; Bianca Conradi; Karsten Rodenacker; Anna A Gorbushina; Karin Schwibbert
Journal:  Materials (Basel)       Date:  2016-09-10       Impact factor: 3.623

2.  Effect of Dissolved Oxygen Concentration on the Microbiologically Influenced Corrosion of Q235 Carbon Steel by Halophilic Archaeon Natronorubrum tibetense.

Authors:  Hongchang Qian; Pengfei Ju; Dawei Zhang; Lingwei Ma; Yuting Hu; Ziyu Li; Luyao Huang; Yuntian Lou; Cuiwei Du
Journal:  Front Microbiol       Date:  2019-04-25       Impact factor: 5.640

3.  Biological and Corrosion Evaluation of In Situ Alloyed NiTi Fabricated through Laser Powder Bed Fusion (LPBF).

Authors:  Agnieszka Chmielewska; Anna Dobkowska; Ewa Kijeńska-Gawrońska; Michał Jakubczak; Agnieszka Krawczyńska; Emilia Choińska; Agnieszka Jastrzębska; David Dean; Bartłomiej Wysocki; Wojciech Święszkowski
Journal:  Int J Mol Sci       Date:  2021-12-08       Impact factor: 5.923

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.