Literature DB >> 23906316

Mono- to Octa-chlorinated PCDD/Fs in stack gas from typical waste incinerators and their implications on emission.

Wenbin Liu1, Zhenyu Tian, Haifeng Li, Huiting Xie, Ke Xiao, Changliang Li, Chen Tang, Minghui Zheng.   

Abstract

Mono- to octa-chlorinated dibenzo-p-dioxins and dibenzofurans (mono- to octa-CDD/Fs) were determined in 14 stack gas samples from two municipal solid waste incinerators and two medical waste incinerators. The total PCDD/F concentrations were 5.1-390 ng/Nm(3), and the mono- to trichlorinated homologues contributed 53.2-94.5% of the total concentrations. The homologue profiles were dominated by the MoCDF, ranged from 1.51 to 113.1 ng/Nm(3), and the proportion that each PCDF homologue group contributed to the total concentration decreased with increasing chlorination level. The toxic equivalent concentrations (I-TEQs) were 0.01-2.81 ng I-TEQ/Nm(3), with 2,3,4,7,8-PeCDF being the biggest contributor, at 30.6-60.0%. Correlations were found among the PCDD/PCDF ratios (D/F ratios), the degree of chlorination, and the TEQ. Stack gases with low I-TEQs had higher proportions of the less chlorinated homologues and lower D/F ratios, which could be attributed to the removal of the more chlorinated isomers by the air pollution control systems used by the incinerators. 2,8-DiCDF, 2,4,8-TrCDF, DiCDF, and TrCDF can be used as TEQ indicators for monitoring PCDD/Fs. 2,8-DiCDF and 2,4,8-TrCDF correlated well with the TEQ because they strongly correlated with 2,3,4,7,8-PeCDF, implying possible correlations in their formation mechanisms.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23906316     DOI: 10.1021/es402136s

Source DB:  PubMed          Journal:  Environ Sci Technol        ISSN: 0013-936X            Impact factor:   9.028


  6 in total

1.  Emission and distribution of PCDD/Fs, chlorobenzenes, chlorophenols, and PAHs from stack gas of a fluidized bed and a stoker waste incinerator in China.

Authors:  Tianjiao Wang; Tong Chen; Xiaoqing Lin; Mingxiu Zhan; Xiaodong Li
Journal:  Environ Sci Pollut Res Int       Date:  2016-12-29       Impact factor: 4.223

2.  Concentrations of and health risks posed by polychlorinated dibenzo-p-dioxins and dibenzofurans around industrial sites in Hebei Province, China.

Authors:  Ying Han; Wenbin Liu; Hans Chr Bruun Hansen; Xuebin Chen; Xiao Liao; Haifeng Li; Mengjing Wang; Nan Yan
Journal:  Environ Sci Pollut Res Int       Date:  2016-06-17       Impact factor: 4.223

3.  Measurement of Dioxin Emissions from a Small-Scale Waste Incinerator in the Absence of Air Pollution Controls.

Authors:  Gang Zhang; Xiangxuan Huang; Wenbo Liao; Shimin Kang; Mingzhong Ren; Jing Hai
Journal:  Int J Environ Res Public Health       Date:  2019-04-09       Impact factor: 3.390

4.  Emission characteristics of harmful air pollutants from cremators in Beijing, China.

Authors:  Yifeng Xue; Linglong Cheng; Xi Chen; Xiaoman Zhai; Wei Wang; Wenjie Zhang; Yan Bai; Hezhong Tian; Lei Nie; Shihao Zhang; Tong Wei
Journal:  PLoS One       Date:  2018-05-02       Impact factor: 3.240

5.  Comprehensive diagnosis of PCDD/F emission from three hazardous waste incinerators.

Authors:  Xuan Cao; Longjie Ji; Xiaoqing Lin; William R Stevens; Minghui Tang; Fanjie Shang; Shaofu Tang; Shengyong Lu
Journal:  R Soc Open Sci       Date:  2018-07-11       Impact factor: 2.963

6.  Characteristics and control measures of odor emissions from crematoriums in Beijing, China.

Authors:  Yangyang Cui; Xiaoman Zhai; Baocheng Wang; Shihao Zhang; Amanzheli Yeerken; Xizi Cao; Lianhong Zhong; Liming Wang; Tong Wei; Xinyu Liu; Yifeng Xue
Journal:  SN Appl Sci       Date:  2021-07-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.