Comparison of the normal sinus node with seven types of rate responsive pacemaker during everyday activity.

A N Sulke1, A Pipilis, R A Henderson, C A Bucknall, E Sowton.   

Abstract

The heart rate response of 59 patients aged 17-79 years implanted with seven different types of rate responsive pacemakers was evaluated during graded exercise treadmill testing and during standardised daily activities. The heart rate response in patients with pacemakers was compared with the chronotropic response in 20 healthy controls of similar age and sex distribution who performed identical protocols. All pacemaker types adequately simulated the control heart rate response during the graded exercise treadmill test except during the early stages of exercise. However, during everyday activities, the response of ventricular rate responsive (VVIR) pacemakers was varied. Activity sensing systems rapidly overresponded to staircase descent, to changes in walking speed, and to suitcase lifting with the pacemaker arm, and these systems did not respond to mental stress. "Physiological" sensors (QT and minute ventilation units) responded slowly to rapid changes in physiological demand. The QT pacemaker patients did respond to mental stress but showed a paradoxical increase in rate during the recovery phases of burst exercise protocols such as staircase ascent/descent and walking deceleration. Dual chamber pacemakers in VDD, DDD, and DDDR modes most closely simulated the normal chronotropic response during everyday activities. Graded exercise treadmill testing, in isolation, may not be the best way to asses or program the heart rate response in patients with the heart rate adaptive pacemakers because changes in heart rate during everyday activities may deviate considerably from the normal sinus response despite satisfactory simulation of the normal chronotropic response during treadmill testing.

Entities:  

Mesh:

Year:  1990        PMID: 2390399      PMCID: PMC1024284          DOI: 10.1136/hrt.64.1.25

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  22 in total

1.  Rate adaptive pacing--clinical experience with three different pacing systems.

Authors:  B Maisch; H Langenfeld
Journal:  Pacing Clin Electrophysiol       Date:  1986-11       Impact factor: 1.976

Review 2.  Rate-responsive pacing: biosensor reliability and physiological sensitivity.

Authors:  P Rossi
Journal:  Pacing Clin Electrophysiol       Date:  1987-05       Impact factor: 1.976

3.  Myocardial demands of atrial-triggered versus fixed-rate ventricular pacing in patients with complete heart block.

Authors:  R Nordlander; S K Pehrsson; H Aström; J Karlsson
Journal:  Pacing Clin Electrophysiol       Date:  1987-09       Impact factor: 1.976

4.  Assessment of the work capacity and relationship between rate response and exercise tolerance associated with activity-sensing rate-responsive ventricular pacing.

Authors:  S Faerestrand; K Breivik; O J Ohm
Journal:  Pacing Clin Electrophysiol       Date:  1987-11       Impact factor: 1.976

5.  Control of pacemaker rate by impedance-based respiratory minute ventilation.

Authors:  E Alt; M Heinz; C Hirgstetter; H P Emslander; S Daum; H Blömer
Journal:  Chest       Date:  1987-08       Impact factor: 9.410

6.  Randomised crossover trial of rate responsive Activitrax and conventional fixed rate ventricular pacing.

Authors:  D P Lipkin; N Buller; M Frenneaux; L Ludgate; T Lowe; S C Webb; D M Krikler
Journal:  Br Heart J       Date:  1987-12

7.  Haemodynamic effect of atrail triggered versus fixed rate pacing at rest and during exercise in complete heart block.

Authors:  I Karlöf
Journal:  Acta Med Scand       Date:  1975-03

8.  Increase in cardiac output with rate-responsive pacemaker.

Authors:  F Beyersdorf; J Kreuzer; T A Happ; M Zegelman; P Satter
Journal:  Ann Thorac Surg       Date:  1986-08       Impact factor: 4.330

9.  Survival and follow-up after pacemaker implantation: a comparison of patients with sick sinus syndrome, complete heart block, and atrial fibrillation.

Authors:  E Alt; R Völker; A Wirtzfeld; K Ulm
Journal:  Pacing Clin Electrophysiol       Date:  1985-11       Impact factor: 1.976

10.  Rate control of physiologic pacemakers by central venous blood temperature.

Authors:  E Alt; C Hirgstetter; M Heinz; H Blömer
Journal:  Circulation       Date:  1986-06       Impact factor: 29.690

View more
  2 in total

1.  Advances in rate responsive pacing?

Authors:  M Griffith
Journal:  Br Heart J       Date:  1994-11

Review 2.  Dual chamber versus single chamber ventricular pacemakers for sick sinus syndrome and atrioventricular block.

Authors:  J Dretzke; W D Toff; G Y H Lip; J Raftery; A Fry-Smith; R Taylor
Journal:  Cochrane Database Syst Rev       Date:  2004
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.