Literature DB >> 23903584

Development of a new selective coronary perfusion cannula.

Nobuo Kondo1, Masaki Yamamoto, Kazuki Kihara, Seiichiro Wariishi, Takashi Fukutomi, Hideaki Nishimori, Kazumasa Orihashi, Tomotaka Takeshima, Kazuhiro Imakubo, Kazunori Aki.   

Abstract

The two most common types of coronary perfusion cannulae currently being used are the "balloon type", with a balloon at the tip, and the "fenestrated type", which has holes along the side near the tip. However, on occasion an unusually high perfusion pressure or a considerable amount of leakage is encountered during infusion of the cardioplegic solution. We have examined the properties of a newly developed Kochi Medical School (KMS)-type cannula and compared these to the properties of the balloon-type and fenestrated-type cannulae in an ex vivo experimental model that contains ostia of 4, 3, or 2 mm in diameter. Ejected flow velocity, circuit pressure, and the amount of leakage were measured at an infusion rate of 100 and 200 mL/min, with the latter two parameters measured under the counterpressure of 0 and 50 cmH2O to examine the influence of coronary vascular resistance. Without counterpressure, the balloon type presented with the highest flow velocity (263 cm/s at 200 mL/min) and perfusion pressure (64 mmHg at 200 mL/min) but without leakage. The fenestrated type yielded a considerable amount of leakage (40 % at an ostium size of 2 mm). The KMS type showed a lower flow velocity and circuit pressure with less leakage. Under 50 cmH2O counterpressure, however, only the KMS-type cannula could inject the water to any ostium size at both flow rates. These results suggest that the concept of the KMS-type cannula may be advantageous to achieving a secure infusion to a diseased coronary ostium.

Entities:  

Mesh:

Year:  2013        PMID: 23903584     DOI: 10.1007/s10047-013-0721-5

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  6 in total

1.  Late iatrogenic coronary stenosis after selective intraoperative antegrade myocardial protection for stentless aortic valve replacement.

Authors:  Simon Maltais; Ismail El-Hamamsy; Anique Ducharme; Michel Carrier; Michel Pellerin; Louis P Perrault
Journal:  J Thorac Cardiovasc Surg       Date:  2006-08       Impact factor: 5.209

2.  Selective antegrade cardioplegic perfusion complicated by left main stem dissection.

Authors:  B P van Putte; A Vink; P C De Bruin; J J A Defauw
Journal:  J Cardiovasc Surg (Torino)       Date:  2007-04       Impact factor: 1.888

3.  Cannulation-induced coronary artery dissection: successful management with circulatory assist devices and coronary bypass grafting.

Authors:  K Ishino; T Murakami; S Teramoto
Journal:  Surg Today       Date:  1998       Impact factor: 2.549

4.  Postperfusion coronary ostial stenosis: incidence and significance.

Authors:  A I Midell; A DeBoer; G Bermudez
Journal:  J Thorac Cardiovasc Surg       Date:  1976-07       Impact factor: 5.209

5.  Early reoperation for iatrogenic left main stenosis after aortic valve replacement: a perilous situation.

Authors:  O Chavanon; M Carrier; R Cartier; Y Hébert; M Pellerin; L P Perrault
Journal:  Cardiovasc Surg       Date:  2002-06

6.  [Successful patch angioplasty for the right coronary artery dissection following selective coronary perfusion].

Authors:  M Nakano; M Matsui; H Okuyama; S Isii; T Itoh; H Kurosawa
Journal:  Kyobu Geka       Date:  1994-02
  6 in total
  1 in total

Review 1.  Journal of Artificial Organs 2013: the year in review : Journal of Artificial Organs Editorial Committee.

Authors:  Y Sawa; E Tatsumi; T Tsukiya; K Matsuda; K Fukunaga; A Kishida; T Masuzawa; G Matsumiya; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2014-02-26       Impact factor: 1.731

  1 in total