Literature DB >> 23902603

Continuous glucose monitoring system (CGMS) in kidney-transplanted children.

Krisztina Pasti1, Attila J Szabo, Agnes Prokai, Krisztina Meszaros, Nora Peko, Reka Solyom, Peter Sallay, György Reusz, Krisztina Rusai.   

Abstract

NODAT and IGT are well-known complications of immunosuppressive therapy after transplantation being a risk factor for cardiovascular disease affecting patient and graft survival. Therefore, early identification and treatment are of high importance. In this study, we examined the glycemic homeostasis of 20 renal-transplanted children using routine laboratory tests and the continuous glucose monitoring system (CGMS). Six patients (30%) had IGT, and one patient had NODAT (5%). The HOMA index was in an abnormal range in 35% of all patients and was abnormal in 67% of the IGT patients. CGMS analysis showed that IGT patients had higher "lowest glucose" level, and the incidence of hypoglycemic episodes was significantly lower compared with patients with normal OGTT result. In IGT patients, glucose variability tended to be lower. Furthermore, in the whole patient cohort, glucose variability significantly decreased with time after transplantation. Summarizing, these novel data show that "lowest glucose" level and hypoglycemic episodes are significantly influenced and altered in renal-transplanted patients with IGT. Furthermore, there is a decrease in glucose variability with time after transplantation. The mechanism and relevance of these data need further investigations.
© 2013 John Wiley & Sons A/S.

Entities:  

Keywords:  continous glucose monitoring; glycemic control; renal transplantation

Mesh:

Substances:

Year:  2013        PMID: 23902603     DOI: 10.1111/petr.12106

Source DB:  PubMed          Journal:  Pediatr Transplant        ISSN: 1397-3142


  4 in total

Review 1.  The diagnosis of posttransplantation diabetes mellitus: meeting the challenges.

Authors:  J Werzowa; M Hecking; M Haidinger; D Döller; A Sharif; A Tura; M D Säemann
Journal:  Curr Diab Rep       Date:  2015-05       Impact factor: 4.810

Review 2.  Metabolic Disorders with Kidney Transplant.

Authors:  Elizabeth Cohen; Maria Korah; Glenda Callender; Renata Belfort de Aguiar; Danielle Haakinson
Journal:  Clin J Am Soc Nephrol       Date:  2020-04-13       Impact factor: 8.237

Review 3.  Continuous glucose monitoring system and new era of early diagnosis of diabetes in high risk groups.

Authors:  Ashraf Soliman; Vincenzo DeSanctis; Mohamed Yassin; Rania Elalaily; Nagwa E Eldarsy
Journal:  Indian J Endocrinol Metab       Date:  2014-05

4.  The Degree of Hyperglycemia Excursion in Patients of Kidney Transplantation (KT) or Liver Transplantation (LT) Assessed by Continuous Glucose Monitoring (CGM): Pilot Study.

Authors:  Heung Yong Jin; Kyung Ae Lee; Yu Ji Kim; Tae Sun Park; Sik Lee; Sung Kwang Park; Hong Pil Hwang; Jae Do Yang; Sung-Woo Ahn; Hee Chul Yu
Journal:  J Diabetes Res       Date:  2019-11-27       Impact factor: 4.011

  4 in total