Literature DB >> 23902542

Continuous monitoring of cardiac rhythms in left ventricular assist device patients.

Francesco Moscato1, Marcus Granegger, Michael Edelmayer, Daniel Zimpfer, Heinrich Schima.   

Abstract

Monitoring of cardiac rhythms is of major importance in the treatment of heart failure patients with left ventricular assist devices (LVADs) implanted. A continuous surveillance of these rhythms could improve out-of-hospital care in these patients. The aim of this study was to investigate cardiac rhythms using available pump data only. Datasets (n = 141) obtained in the normal ward, in the intensive care unit, and during bicycle ergometry were analyzed in 11 recipients of a continuous flow LVAD (59.1 ± 9.7 years; male 82%). Tachograms and arrhythmic patterns derived from the pump flow waveform, and a simultaneously recorded ECG were compared, as well as heart rate variability parameters such as: the average heart beat duration (RR interval), the standard deviation of the beat duration (SDNN), the root-mean-square of the difference of successive beat durations (RMSSD), and the number of pairs of adjacent beat duration differing by >50 ms divided by the number of all beats (pNN50). A very good agreement of cardiac rhythm parameters from the pump flow compared with ECG was found. Tachycardia, atrial fibrillation, and extrasystoles could be accurately identified from the tachograms derived from the pump flow. Also, Bland-Altman analysis comparing pump flow with ECG indicated a very small difference in average RR interval of 0.3 ± 1.0 ms, in SSDN of 0.5 ± 2.7 ms, in RMSSD of 1.0 ± 5.6 ms, and in pNN50 of 0.3 ± 1.0%. Continuous monitoring of cardiac rhythms from available pump data is possible. It has the potential to reduce the out-of-hospital diagnostic burden and to permit a more efficient adjustment of the level of mechanical support.
© 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

Entities:  

Keywords:  Arrhythmia; Cardiac rhythms; Continuous monitoring; Heart failure; Ventricular assist device

Mesh:

Year:  2013        PMID: 23902542     DOI: 10.1111/aor.12141

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  7 in total

Review 1.  The left ventricular assist device as a patient monitoring system.

Authors:  Francesco Moscato; Christoph Gross; Martin Maw; Thomas Schlöglhofer; Marcus Granegger; Daniel Zimpfer; Heinrich Schima
Journal:  Ann Cardiothorac Surg       Date:  2021-03

2.  A Sensorless Modular Multiobjective Control Algorithm for Left Ventricular Assist Devices: A Clinical Pilot Study.

Authors:  Martin Maw; Thomas Schlöglhofer; Christiane Marko; Philipp Aigner; Christoph Gross; Gregor Widhalm; Anne-Kristin Schaefer; Michael Schima; Franziska Wittmann; Dominik Wiedemann; Francesco Moscato; D'Anne Kudlik; Robert Stadler; Daniel Zimpfer; Heinrich Schima
Journal:  Front Cardiovasc Med       Date:  2022-04-25

3.  Initial experience with telemonitoring in left ventricular assist device patients.

Authors:  Stephan Hohmann; Christian Veltmann; David Duncker; Thorben König; Dominik Berliner; Jasmin Hanke; Günes Dogan; Anamika Chatterjee; Christina Feldmann; Bryan Lynch; Daniel Burkhoff; Axel Haverich; Johann Bauersachs; Jan D Schmitto
Journal:  J Thorac Dis       Date:  2019-04       Impact factor: 2.895

4.  LVAD Pump Flow Does Not Adequately Increase With Exercise.

Authors:  Christoph Gross; Christiane Marko; Johann Mikl; Johann Altenberger; Thomas Schlöglhofer; Heinrich Schima; Daniel Zimpfer; Francesco Moscato
Journal:  Artif Organs       Date:  2018-11-18       Impact factor: 3.094

Review 5.  The History of Durable Left Ventricular Assist Devices and Comparison of Outcomes: HeartWare, HeartMate II, HeartMate 3, and the Future of Mechanical Circulatory Support.

Authors:  Cecilia Berardi; Claudio A Bravo; Song Li; Maziar Khorsandi; Jeffrey E Keenan; Jonathan Auld; Sunny Rockom; Jennifer A Beckman; Claudius Mahr
Journal:  J Clin Med       Date:  2022-04-05       Impact factor: 4.241

6.  Continuous LVAD monitoring reveals high suction rates in clinically stable outpatients.

Authors:  Christoph Gross; Heinrich Schima; Thomas Schlöglhofer; Kamen Dimitrov; Martin Maw; Julia Riebandt; Dominik Wiedemann; Daniel Zimpfer; Francesco Moscato
Journal:  Artif Organs       Date:  2020-03-01       Impact factor: 3.094

7.  Hemodynamic exercise responses with a continuous-flow left ventricular assist device: Comparison of patients' response and cardiorespiratory simulations.

Authors:  Christoph Gross; Libera Fresiello; Thomas Schlöglhofer; Kamen Dimitrov; Christiane Marko; Martin Maw; Bart Meyns; Dominik Wiedemann; Daniel Zimpfer; Heinrich Schima; Francesco Moscato
Journal:  PLoS One       Date:  2020-03-18       Impact factor: 3.240