Literature DB >> 23902540

A minimally invasive method for clinical trans-diaphragmatic pressure measurement in anaesthetized dogs.

Kiriaki Pavlidou1, Ioannis Savvas, Yves Moens, Dimitrios Vasilakos, Dimitrios Raptopoulos.   

Abstract

OBJECTIVE: To measure trans-diaphragmatic pressures, as an indication of diaphragmatic contractility, in anaesthetized dogs breathing normally, or during inspiratory obstruction (Mueller's manoeuvre) in order to assess if the method is practicable for use in clinical circumstances. STUDY
DESIGN: Pilot study. ANIMALS: Twenty eight client-owned dogs, ASA I or II, 1-10 years old, 5-30 kg bodyweight, which required anaesthesia for surgery, and were to be positioned in lateral recumbency.
METHODS: Following a standardized regimen of premedication and anaesthetic induction, anaesthesia was stabilized and maintained with isoflurane. Two commercially available balloon catheters were introduced orally, and advanced, one into the stomach and one into the mid-third of the oesophagus. Oesophageal and gastric pressures were measured from these catheters, and trans-diaphragmatic pressure (Pdi ) calculated and recorded continuously. At three separate time points during anaesthesia, for one breath, inspiration was obstructed (Mueller's manoeuvre) and Pdi was measured.
RESULTS: Placement of the catheters in the stomach was not easy, and failed in three cases. In five dogs, their size resulted in failure of correct placement of catheters. Good traces of all three pressures reflecting respiratory cycles were obtained from 20 dogs. During normal spontaneous breathing (mean ± SD [range]) Pdi was 5 ± 2.1 (3-10) mmHg. During Mueller's manoeuvre, Pdi was 14.6 ± 4.5 (9-21) mmHg. Abnormal waveforms were seen included cardiac oscillations (five dogs), inadequate intra-gastric pressure tracing (one dog), deflections with a double peak (one dog), and multiple artifacts when there was increased heart rate and tachypnoea (two dogs in response to surgery). CONCLUSIONS AND CLINICAL RELEVANCE: Measurement of trans-diaphragmatic pressure with balloon catheters was practicable in suitably sized dogs anaesthetized for clinical purposes and might be a useful tool in the assessment of diaphragmatic function. A range of catheters are required if the technique is to work in all dogs.
© 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

Entities:  

Keywords:  Dog; balloon catheters; intra-gastric pressure; intra-oesophageal pressure; trans-diaphragmatic pressure

Mesh:

Year:  2013        PMID: 23902540     DOI: 10.1111/vaa.12073

Source DB:  PubMed          Journal:  Vet Anaesth Analg        ISSN: 1467-2987            Impact factor:   1.648


  2 in total

1.  Ultrasound assessment of the diaphragm: Preliminary study of a canine model of X-linked myotubular myopathy.

Authors:  Aarti Sarwal; Michael S Cartwright; Francis O Walker; Erin Mitchell; Anna Buj-Bello; Alan H Beggs; Martin K Childers
Journal:  Muscle Nerve       Date:  2014-08-30       Impact factor: 3.217

2.  The effect of four anaesthetic protocols for maintenance of anaesthesia on trans-diaphragmatic pressure in dogs.

Authors:  Kiriaki Pavlidou; Ioannis Savvas; Yves P S Moens; Dimitrios Vasilakos; Dimitrios Raptopoulos
Journal:  PLoS One       Date:  2013-10-04       Impact factor: 3.240

  2 in total