Literature DB >> 23900976

Improved quantification precision of human brain short echo-time (1) H magnetic resonance spectroscopy at high magnetic field: a simulation study.

Dinesh Kumar Deelchand1, Isabelle Iltis, Pierre-Gilles Henry.   

Abstract

PURPOSE: The gain in quantification precision that can be expected in human brain (1) H MRS at very high field remains a matter of debate. Here, we investigate this issue using Monte-Carlo simulations.
METHODS: Simulated human brain-like (1) H spectra were fitted repeatedly with different noise realizations using LCModel at B0 ranging from 1.5T to 11.7T, assuming a linear increase in signal-to-noise ratio with B0 in the time domain, and assuming a linear increase in linewidth with B0 based on experimental measurements. Average quantification precision (Cramér-Rao lower bound) was then determined for each metabolite as a function of B0 .
RESULTS: For singlets, Cramér-Rao lower bounds improved (decreased) by a factor of ∼ B0 as B0 increased, as predicted by theory. For most J-coupled metabolites, Cramér-Rao lower bounds decreased by a factor ranging from B0 to B0 as B0 increased, reflecting additional gains in quantification precision compared to singlets owing to simplification of spectral pattern and reduced overlap.
CONCLUSIONS: Quantification precision of (1) H magnetic resonance spectroscopy in human brain continues to improve with B0 up to 11.7T although peak signal-to-noise ratio in the frequency domain levels off above 3T. In most cases, the gain in quantification precision is higher for J-coupled metabolites than for singlets.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  1H magnetic resonance spectroscopy; Cramér-Rao Lower Bounds; Monte-Carlo simulations; human brain; quantification precision

Mesh:

Year:  2013        PMID: 23900976      PMCID: PMC3907456          DOI: 10.1002/mrm.24892

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  Cramer-Rao bound expressions for parametric estimation of overlapping peaks: influence of prior knowledge

Authors: 
Journal:  J Magn Reson       Date:  2000-04       Impact factor: 2.229

2.  Comparison of the quantification precision of human short echo time (1)H spectroscopy at 1.5 and 4.0 Tesla.

Authors:  R Bartha; D J Drost; R S Menon; P C Williamson
Journal:  Magn Reson Med       Date:  2000-08       Impact factor: 4.668

3.  In vivo 1H NMR spectroscopy of the human brain at 7 T.

Authors:  I Tkác; P Andersen; G Adriany; H Merkle; K Ugurbil; R Gruetter
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

4.  MR spectroscopy of the human brain with enhanced signal intensity at ultrashort echo times on a clinical platform at 3T and 7T.

Authors:  Ralf Mekle; Vladimír Mlynárik; Giulio Gambarota; Martin Hergt; Gunnar Krueger; Rolf Gruetter
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

5.  Short-echo, single-shot, full-intensity proton magnetic resonance spectroscopy for neurochemical profiling at 4 T: validation in the cerebellum and brainstem.

Authors:  Gülin Oz; Ivan Tkáč
Journal:  Magn Reson Med       Date:  2010-11-30       Impact factor: 4.668

6.  In vivo 1H NMR spectroscopy of the human brain at 9.4 T: initial results.

Authors:  Dinesh Kumar Deelchand; Pierre-François Van de Moortele; Gregor Adriany; Isabelle Iltis; Peter Andersen; John P Strupp; J Thomas Vaughan; Kâmil Uğurbil; Pierre-Gilles Henry
Journal:  J Magn Reson       Date:  2010-06-10       Impact factor: 2.229

7.  High magnetic field water and metabolite proton T1 and T2 relaxation in rat brain in vivo.

Authors:  Robin A de Graaf; Peter B Brown; Scott McIntyre; Terence W Nixon; Kevin L Behar; Douglas L Rothman
Journal:  Magn Reson Med       Date:  2006-08       Impact factor: 4.668

8.  Signal-to-noise ratio and spectral linewidth improvements between 1.5 and 7 Tesla in proton echo-planar spectroscopic imaging.

Authors:  Ricardo Otazo; Bryon Mueller; Kamil Ugurbil; Lawrence Wald; Stefan Posse
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

9.  Resolution improvements in in vivo 1H NMR spectra with increased magnetic field strength.

Authors:  R Gruetter; S A Weisdorf; V Rajanayagan; M Terpstra; H Merkle; C L Truwit; M Garwood; S L Nyberg; K Uğurbil
Journal:  J Magn Reson       Date:  1998-11       Impact factor: 2.229

10.  Proton MR spectroscopy in mild cognitive impairment and Alzheimer disease: comparison of 1.5 and 3 T.

Authors:  Kejal Kantarci; Glenn Reynolds; Ronald C Petersen; Bradley F Boeve; David S Knopman; Steven D Edland; Glenn E Smith; Robert J Ivnik; Eric G Tangalos; Clifford R Jack
Journal:  AJNR Am J Neuroradiol       Date:  2003-05       Impact factor: 3.825

View more
  7 in total

1.  Sensitivity and specificity of human brain glutathione concentrations measured using short-TE (1)H MRS at 7 T.

Authors:  Dinesh K Deelchand; Małgorzata Marjańska; James S Hodges; Melissa Terpstra
Journal:  NMR Biomed       Date:  2016-02-22       Impact factor: 4.044

2.  Measurement of Hypothalamic Glucose Under Euglycemia and Hyperglycemia by MRI at 3T.

Authors:  James M Joers; Dinesh K Deelchand; Anjali Kumar; Amir Moheet; Elizabeth Seaquist; Pierre-Gilles Henry; Gülin Öz
Journal:  J Magn Reson Imaging       Date:  2016-07-12       Impact factor: 4.813

3.  Two-site reproducibility of cerebellar and brainstem neurochemical profiles with short-echo, single-voxel MRS at 3T.

Authors:  Dinesh K Deelchand; Isaac M Adanyeguh; Uzay E Emir; Tra-My Nguyen; Romain Valabregue; Pierre-Gilles Henry; Fanny Mochel; Gülin Öz
Journal:  Magn Reson Med       Date:  2014-06-19       Impact factor: 4.668

4.  Test-retest reproducibility of neurochemical profiles with short-echo, single-voxel MR spectroscopy at 3T and 7T.

Authors:  Melissa Terpstra; Ian Cheong; Tianmeng Lyu; Dinesh K Deelchand; Uzay E Emir; Petr Bednařík; Lynn E Eberly; Gülin Öz
Journal:  Magn Reson Med       Date:  2015-10-26       Impact factor: 4.668

5.  Proton magnetic resonance spectroscopy assessment of metabolite status of the anterior cingulate cortex in chronic pain patients and healthy controls.

Authors:  Takahiro Ito; Sachiko Tanaka-Mizuno; Narihito Iwashita; Ikuo Tooyama; Akihiko Shiino; Katsuyuki Miura; Sei Fukui
Journal:  J Pain Res       Date:  2017-01-31       Impact factor: 3.133

6.  The influence of spatial resolution on the spectral quality and quantification accuracy of whole-brain MRSI at 1.5T, 3T, 7T, and 9.4T.

Authors:  Stanislav Motyka; Philipp Moser; Lukas Hingerl; Gilbert Hangel; Eva Heckova; Bernhard Strasser; Korbinian Eckstein; Simon Daniel Robinson; Benedikt A Poser; Stephan Gruber; Siegfried Trattnig; Wolfgang Bogner
Journal:  Magn Reson Med       Date:  2019-04-01       Impact factor: 4.668

7.  Feasibility of Glutamate and GABA Detection in Pons and Thalamus at 3T and 7T by Proton Magnetic Resonance Spectroscopy.

Authors:  Samaira Younis; Anders Hougaard; Casper E Christensen; Mark B Vestergaard; Esben T Petersen; Vincent O Boer; Olaf B Paulson; Messoud Ashina; Anouk Marsman; Henrik B W Larsson
Journal:  Front Neurosci       Date:  2020-10-23       Impact factor: 4.677

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.