Literature DB >> 23899610

Experimental assessment of CT-based thermometry during laser ablation of porcine pancreas.

E Schena1, P Saccomandi, F Giurazza, M A Caponero, L Mortato, F M Di Matteo, F Panzera, R Del Vescovo, B Beomonte Zobel, S Silvestri.   

Abstract

Laser interstitial thermotherapy (LITT) is employed to destroy tumors in organs, and its outcome strongly depends on the temperature distribution inside the treated tissue. The recent introduction of computed tomography (CT) scan thermometry, based on the CT number dependence of the tissue with temperature, overcomes the invasiveness of other techniques used to monitor temperature during LITT. The averaged CT number (ROI = 0.02 cm(2)) of an ex vivo swine pancreas is monitored during LITT (Nd:YAG laser power of 3 W, treatment time: 120 s) at different distances from the applicator (from 4 to 30 mm). The averaged CT number shows a clear decrease during treatment: it is highest at 4 mm from the applicator (mean variation in the whole treatment of -0.256 HU s(-1)) and negligible at 30 mm, since the highest temperature increase is present close to the applicator (i.e., 45 °C at 4 mm and 25 °C at 6 mm). To obtain the relationship between CT numbers and pancreas temperature, the reference temperature was measured by 12 fiber Bragg grating sensors. The CT number decreases as a function of temperature, showing a nonlinear trend with a mean thermal sensitivity of -0.50 HU °C(-1). Results here reported are the first assessment of pancreatic CT number dependence on temperature, at the best of our knowledge. Findings can be useful to further investigate CT scan thermometry during LITT on the pancreas.

Entities:  

Mesh:

Year:  2013        PMID: 23899610     DOI: 10.1088/0031-9155/58/16/5705

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

Review 1.  Imaging-based internal body temperature measurements: The journal Temperature toolbox.

Authors:  Juho Raiko; Kalle Koskensalo; Teija Sainio
Journal:  Temperature (Austin)       Date:  2020-05-29

2.  Analysis of iodinated contrast delivered during thermal ablation: is material trapped in the ablation zone?

Authors:  Po-Hung Wu; Chris L Brace
Journal:  Phys Med Biol       Date:  2016-07-25       Impact factor: 3.609

3.  Temperature monitoring during microwave ablation in ex vivo porcine livers.

Authors:  P Saccomandi; E Schena; C Massaroni; Y Fong; R F Grasso; F Giurazza; B Beomonte Zobel; X Buy; J Palussiere; R L Cazzato
Journal:  Eur J Surg Oncol       Date:  2015-09-25       Impact factor: 4.424

4.  Preliminary analysis of ultrasound elastography imaging-based thermometry on non-perfused ex vivo swine liver.

Authors:  Francesco Giurazza; Carlo Massaroni; Sergio Silvestri; Bruno Beomonte Zobel; Emiliano Schena
Journal:  J Ultrasound       Date:  2019-09-20

5.  Feature-based automated segmentation of ablation zones by fuzzy c-mean clustering during low-dose computed tomography.

Authors:  Po-Hung Wu; Mariajose Bedoya; Jim White; Christopher L Brace
Journal:  Med Phys       Date:  2020-12-18       Impact factor: 4.071

Review 6.  Emerging clinical applications of computed tomography.

Authors:  Carlo Liguori; Giulia Frauenfelder; Carlo Massaroni; Paola Saccomandi; Francesco Giurazza; Francesca Pitocco; Riccardo Marano; Emiliano Schena
Journal:  Med Devices (Auckl)       Date:  2015-06-05

Review 7.  Perspectives of breast cancer thermotherapies.

Authors:  Edouard Alphandéry
Journal:  J Cancer       Date:  2014-05-29       Impact factor: 4.207

Review 8.  Laser Ablation for Cancer: Past, Present and Future.

Authors:  Emiliano Schena; Paola Saccomandi; Yuman Fong
Journal:  J Funct Biomater       Date:  2017-06-14

Review 9.  Optical fiber-based MR-compatible sensors for medical applications: an overview.

Authors:  Fabrizio Taffoni; Domenico Formica; Paola Saccomandi; Giovanni Di Pino; Emiliano Schena
Journal:  Sensors (Basel)       Date:  2013-10-18       Impact factor: 3.576

Review 10.  Fiber Optic Sensors for Temperature Monitoring during Thermal Treatments: An Overview.

Authors:  Emiliano Schena; Daniele Tosi; Paola Saccomandi; Elfed Lewis; Taesung Kim
Journal:  Sensors (Basel)       Date:  2016-07-22       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.