Literature DB >> 23898020

Development of a sirolimus-eluting poly (L-lactide)/poly(4-hydroxybutyrate) absorbable stent for peripheral vascular intervention.

Niels Grabow, Carsten M Bünger, Sabine Kischkel, J Hinrich Timmermann, Thomas Reske, David P Martin, Simon F Williams, Wolfgang Schareck, Katrin Sternberg, Klaus-Peter Schmitz.   

Abstract

Fully absorbable drug-eluting stent platforms are currently entering the clinical arena for the interventional treatment of coronary artery disease. This new technology also holds potential for application in peripheral vascular settings. Our study reports on the development of a sirolimus- (SIR) eluting absorbable polymer stent made from a blend of poly(l-lactide) and poly(4-hydroxybutyrate) (PLLA/P4HB) for peripheral vascular intervention. Stent prototypes were laser-cut from PLLA/P4HB tubes (I.D.=2.2 mm, t=250 µm), spray-coated with different PLLA/P4HB/SIR solutions, and bench-tested to determine expansion properties, fatigue, trackability and in vitro drug release kinetics. The stent prototypes were expanded with a 5.0 × 20 mm balloon catheter, and exhibited a recoil of 3.6% upon balloon deflation. Stent collapse pressure of 0.4 bar (300 mm Hg) was measured under external pressure load. Sustained scaffolding properties were observed in vitro over 14 weeks of radial fatigue loading (50 ± 25 mm Hg at 1.2 Hz). Trackability was demonstrated in bench tests with an 8 French contralateral introducer sheath. SIR release kinetics were adjusted over a broad range by varying the PLLA/P4HB ratio of the coating matrix. The newly developed absorbable SIR-eluting PLLA/P4HB stent successfully fulfilled the requirements for peripheral vascular intervention under in vitro conditions.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23898020     DOI: 10.1515/bmt-2012-0050

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  2 in total

1.  Biodegradable polymeric stents for vascular application in a porcine carotid artery model: English version.

Authors:  S Kischkel; N Grabow; A Püschel; B Erdle; M Kabelitz; D P Martin; S F Williams; I Bombor; K Sternberg; K-P Schmitz; W Schareck; C M Bünger
Journal:  Gefasschirurgie       Date:  2015-03-18

2.  Influence of Drug Incorporation on the Physico-Chemical Properties of Poly(l-Lactide) Implant Coating Matrices-A Systematic Study.

Authors:  Daniela Arbeiter; Thomas Reske; Michael Teske; Dalibor Bajer; Volkmar Senz; Klaus-Peter Schmitz; Niels Grabow; Stefan Oschatz
Journal:  Polymers (Basel)       Date:  2021-01-18       Impact factor: 4.329

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.