Literature DB >> 23897530

Prospective Evaluation of the radiologist’s hand dose in CT-guided interventions.

B Rogits1, K Jungnickel, D Löwenthal, S Kropf, E A Nekolla, O Dudeck, M Pech, G Wieners, J Ricke.   

Abstract

PURPOSE: Assessment of radiologist's hand dose in CT-guided interventions and determination of influencing factors.
MATERIALS AND METHODS: The following CT-guided interventions were included: Core biopsy, drainage, periradicular therapy, and celiac plexus neurolysis. The hand dose was measured with an immediately readable dosimeter, the EDD-30 (Unfors, Sweden). The default parameters for CT fluoroscopy were 120 kV, 90 mA and a 4 mm slice thickness. All interventions were performed on a 16-slice CT unit (Aquilion 16 Toshiba, Japan). The tumor size, degree of difficulty (1 - 3), level of experience and device parameters (mAs, dose-length product, scan time) were documented.
RESULTS: 138 CT-guided interventions (biopsy n = 99, drainage n = 23, pain therapy n = 16) at different locations (lung n = 41, retroperitoneum n = 53, liver n = 25, spine n = 19) were included. The lesion size was 4 - 240 mm (median: 23 mm). The fluoroscopy time per intervention was 4.6 - 140.2 s (median: 24.2 s). The measured hand dose ranged from 0.001 - 3.02 mSv (median: 0.22 mSv). The median hand dose for lung puncture (n = 41) was slightly higher (median: 0.32 mSv, p = 0.01) compared to that for the liver, retroperitoneum and other. Besides physical influencing factors, the degree of difficulty (p = 0.001) and summed puncture depth (p = 0.004) correlated significantly with the hand dose.
CONCLUSION: The median hand dose for different CT-guided interventions was 0.22 mSv. Therefore, the annual hand dose limit would normally only be reached with about 2000 interventions. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2013        PMID: 23897530     DOI: 10.1055/s-0033-1350368

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  2 in total

1.  Ultra-low-dose periradicular infiltration of the lumbar spine: spot scanning and its potential for further dose reduction by replacing helical planning CT.

Authors:  Fabian Henry Jürgen Elsholtz; Lars-Arne Schaafs; Christoph Erxleben; Bernd Hamm; Stefan Markus Niehues
Journal:  Radiol Med       Date:  2017-04-20       Impact factor: 3.469

2.  Radiation dose reduction for CT-guided intrathecal nusinersen administration in adult patients with spinal muscular atrophy.

Authors:  Isabell Cordts; Marcus Deschauer; Paul Lingor; Egon Burian; Thomas Baum; Claus Zimmer; Christian Maegerlein; Nico Sollmann
Journal:  Sci Rep       Date:  2020-02-25       Impact factor: 4.379

  2 in total