Effects of silicone expanders and implants on echocardiographic image quality after breast reconstruction.

Marco Pignatti1, Francesca Mantovani, Luca Bertelli, Andrea Barbieri, Lucrezia Pacchioni, Pietro Loschi, Giorgio De Santis.   

Abstract

BACKGROUND: Use of silicone expanders and implants is the most common breast reconstruction technique after mastectomy. Postmastectomy patients often need echocardiographic monitoring of potential cardiotoxicity induced by cancer chemotherapy. The impairment of the echocardiographic acoustic window caused by silicone implants for breast augmentation has been reported. This study investigates whether the echocardiographic image quality was impaired in women reconstructed with silicone expanders and implants.
METHODS: The records of 44 consecutive women who underwent echocardiographic follow-up after breast reconstruction with expanders and implants at the authors' institution from January of 2000 to August of 2012 were reviewed. The population was divided into a study group (left or bilateral breast expanders/implants, n=30) and a control group (right breast expanders/implants, n=14). The impact of breast expanders/implants on echocardiographic image quality was tested (analysis of covariance model).
RESULTS: Patients with a breast expander/implant (left or bilateral and right breast expanders/implants) were included. The mean volume of the breast devices was 353.2±125.5 cc. The quality of the echocardiographic images was good or sufficient in the control group; in the study group, it was judged as adequate in only 50 percent of cases (15 patients) and inadequate in the remaining 15 patients (p<0.001). At multivariable analysis, a persistent relationship between device position (left versus right) and image quality (p=0.001) was shown, independent from other factors.
CONCLUSIONS: Silicone expanders and implants in postmastectomy left breast reconstruction considerably reduce the image quality of echocardiography. This may have important clinical implications, given the need for periodic echocardiographic surveillance before and during chemotherapy. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, III.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23897326     DOI: 10.1097/PRS.0b013e31829e7bec

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  3 in total

1.  A Fibrosis Biomarker Early Predicts Cardiotoxicity Due to Anthracycline-Based Breast Cancer Chemotherapy.

Authors:  Ana de la Fuente; Marta Santisteban; Josep Lupón; José Manuel Aramendía; Agnes Díaz; Ana Santaballa; Amparo Hernándiz; Pilar Sepúlveda; Germán Cediel; Begoña López; José María López Picazo; Manuel M Mazo; Gregorio Rábago; Juan José Gavira; Ignacio García-Bolao; Javier Díez; Arantxa González; Antoni Bayés-Genís; Susana Ravassa
Journal:  Cancers (Basel)       Date:  2022-06-14       Impact factor: 6.575

2.  Echocardiography image quality of global longitudinal strain in cardio-oncology: a prospective real-world investigation.

Authors:  Noriko Iida; Kazuko Tajiri; Tomoko Ishizu; Rumi Sasamura-Koshizuka; Hideki Nakajima; Naoto Kawamatsu; Kimi Sato; Masayoshi Yamamoto; Tomoko Machino-Ohtsuka; Hiroko Bando; Ikuo Sekine; Yasushi Kawakami; Masaki Ieda
Journal:  J Echocardiogr       Date:  2022-03-04

3.  Influence of breast reconstruction on technical aspects of echocardiographic image acquisition compared with physician-assessed image quality.

Authors:  Joaquin Duarte Ow; Mohamad Hemu; Anel Yakupovich; Parva Bhatt; Hannah Gaddam; Nicole Prabhu; Ibtihaj Fughhi; Melody Cobleigh; Melissa Tracy; Louis Fogg; Tochukwu Okwuosa
Journal:  Cardiooncology       Date:  2019-11-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.