Literature DB >> 23896622

The preliminary evaluation of a 1 MHz ultrasound probe for measuring the elastic anisotropy of human cortical bone.

M Daugschies1, K Rohde, C-C Glüer, R Barkmann.   

Abstract

Our objective is to evaluate an ultrasound probe for measurements of velocity and anisotropy in human cortical bone (tibia). The anisotropy of cortical bone is a known and mechanically relevant property in the context of osteoporotic fracture risk. Current in vivo quantitative ultrasound devices measuring the velocity of ultrasound in long bones can only be applied in the axial direction. For anisotropy measurements a second direction for velocity measurements preferably perpendicular to the axial direction is necessary. We developed a new ultrasound probe which permits axial transmission measurements with a simultaneous second perpendicular direction (tangential). Anisotropy measurements were performed on isotropic and anisotropic phantoms and two excised human female tibiae (age 63 and 82). Anisotropy ratios (AI; ratio of squared ultrasound velocities in the two directions) were for the isotropic phantom 1.06 ± 0.01 and for the anisotropic phantom 1.14 ± 0.03 (mean ± standard deviation). AI was 1.83 ± 0.29 in the tibia from the older donor and 1.37 ± 0.18 in the tibia from the younger donor. The AIs were in the expected range and differed significantly (p<0.05, t-test) between the tibiae. Measured sound velocities were reproducible (mean standard deviation of short time precision of both channels for phantom measurements 31 m/s) and in agreement with reported velocities of the phantom material. Our results document the feasibility of anisotropy measurements at long bones using a single probe. Further improvements in the design of the probe and tests in vivo are warranted. If this approach can be evaluated in vivo an additional tool for assessing the bone status is available for clinical use.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Elastic anisotropy; Quantitative ultrasound; Sound velocity; Tibia; Ultrasound array

Mesh:

Year:  2013        PMID: 23896622     DOI: 10.1016/j.ultras.2013.07.004

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  3 in total

1.  Ultrasound to assess bone quality.

Authors:  Kay Raum; Quentin Grimal; Peter Varga; Reinhard Barkmann; Claus C Glüer; Pascal Laugier
Journal:  Curr Osteoporos Rep       Date:  2014-06       Impact factor: 5.096

2.  Quantitative ultrasound measurement of bone density based on dynamic time window: suitable for the measurement of speed of sound in radius.

Authors:  Yang Xu; Yubing Xu; Yanyan Chen; Zenghui Ding; Zuchang Ma; Yining Sun
Journal:  J Med Ultrason (2001)       Date:  2016-04-20       Impact factor: 1.314

3.  Preoperative evaluation of bone quality for dental implantation using an ultrasound axial transmission device in an ex vivo model.

Authors:  Shinsuke Okada; Akira Kawano; Hiroshi Oue; Yosuke Takeda; Miyuki Yokoi; Katsunori Koretake; Kazuhiro Tsuga
Journal:  Clin Exp Dent Res       Date:  2017-06-09
  3 in total