Literature DB >> 23893749

Evaluation of the use of a tablet computer with a high-resolution display for interpreting emergency CT scans.

S Tewes, T Rodt, S Marquardt, E Evangelidou, F K Wacker, C von Falck.   

Abstract

PURPOSE: Evaluation of the potential usability of an iPad 3 with a high-resolution display in CT emergency diagnosis compared to a 3 D PACS workstation.
MATERIALS AND METHODS: 3 readers used a 5-point Likert scale to evaluate 40 CCT scans and 40 CTPA scans to determine the detectability of early signs of infarction in CCT or segmental and subsegmental pulmonary embolisms in CT angiography of the pulmonary arteries (CTPA) on the iPad 3 (Apple Inc., USA) using an application for image viewing (Visage Ease, Visage Imaging GmbH, Berlin) and on a 3 D PACS workstation (Visage 7.1, Visage Imaging, Berlin) using a certified monitor for image viewing. The results were compared using the Wilcoxon rank sum test, Spearman's correlation coefficient, and a kappa statistic.
RESULTS: There was no significant difference in the median evaluations for the readings of both the CCT scans and the CTPA scans on the iPad 3 and on the workstation (p > 0.05) for all three readers. The mean Spearman's correlation coefficient for CCT and CTPA was 0.46 (± 0.2) and 0.69 (± 0.16), respectively, for the comparison iPad/PACS, 0.41 (± 0.16) and 0.68 (± 0.06), respectively, for the interobserver agreement on the iPad, and 0.35 (± 0.05) and 0.68 (± 0.10), respectively, for the interobserver agreement on the PACS. Mean kappa values for CCT of 0.52 (± 0.17) for the comparison iPad/PACS and 0.33 (± 0.16) and 0.32 (± 0.16), respectively, for the interobserver agreement on the iPad and the PACS were achieved. For CTPA average kappa values of 0.67 (± 0.19) were calculated for the comparison iPad/PACS and 0.69 (± 0.08) and 0.60 (± 0.14), respectively, for the interobserver concordance on the iPad 3 and the PACS. All differences were not statistically significant (p > 0.05).
CONCLUSION: The variability of the interpretation of typical emergency scans on an iPad 3 with a high-resolution display and on a 3 D PACS workstation does not differ from the interobserver variability. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2013        PMID: 23893749     DOI: 10.1055/s-0033-1350155

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  13 in total

Review 1.  Radiological interpretation of images displayed on tablet computers: a systematic review.

Authors:  L J Caffery; N R Armfield; A C Smith
Journal:  Br J Radiol       Date:  2015-04-17       Impact factor: 3.039

2.  Comparison of medical-grade and calibrated consumer-grade displays for diagnosis of subtle bone fissures.

Authors:  Daniel Pinto Dos Santos; Jonas Welter; Tilman Emrich; Florian Jungmann; Evelyn Dappa; Peter Mildenberger; Roman Kloeckner
Journal:  Eur Radiol       Date:  2017-06-28       Impact factor: 5.315

3.  The effect of time in use on the display performance of the iPad.

Authors:  Liam J Caffery; Kenneth L Manthey; Lawrence H Sim
Journal:  Br J Radiol       Date:  2016-05-16       Impact factor: 3.039

4.  Mobile Image Interpretation: Diagnostic Performance of CT Exams Displayed on a Tablet Computer in Detecting Abdominopelvic Hemorrhage.

Authors:  Philipp M Schlechtweg; Ferdinand J Kammerer; Hannes Seuss; Michael Uder; Matthias Hammon
Journal:  J Digit Imaging       Date:  2016-04       Impact factor: 4.056

5.  Remote reading of coronary CTA exams using a tablet computer: utility for stenosis assessment and identification of coronary anomalies.

Authors:  Stefan L Zimmerman; Cheng T Lin; Linda C Chu; John Eng; Elliot K Fishman
Journal:  Emerg Radiol       Date:  2016-04-16

6.  Tablets for Image Review and Communication in Daily Routine of Orthopedic Surgeons-An Evaluation Study.

Authors:  Sven Y Vetter; Svenja Schüler; Matthes Hackbusch; Michael Müller; Benedict Swartman; Marc Schnetzke; Paul Alfred Grützner; Jochen Franke
Journal:  J Digit Imaging       Date:  2018-02       Impact factor: 4.056

7.  iPad-based primary 2D reading of CT angiography examinations of patients with suspected acute gastrointestinal bleeding: preliminary experience.

Authors:  L Faggioni; E Neri; I Bargellini; P Scalise; F Calcagni; A Mantarro; G D'Ippolito; C Bartolozzi
Journal:  Br J Radiol       Date:  2015-03       Impact factor: 3.039

8.  Effect of display type and room illuminance in chest radiographs.

Authors:  Esa Liukkonen; Airi Jartti; Marianne Haapea; Heljä Oikarinen; Lauri Ahvenjärvi; Seija Mattila; Terhi Nevala; Kari Palosaari; Marja Perhomaa; Miika T Nieminen
Journal:  Eur Radiol       Date:  2015-12-10       Impact factor: 5.315

9.  Ruling Out Brain CT Contraindications prior to Intravenous Thrombolysis: Diagnostic Equivalence between a Primary Interpretation Workstation and a Mobile Tablet Computer.

Authors:  Antonio J Salazar; Nicolás Useche; Manuel Granja; Aníbal J Morillo; Sonia Bermúdez
Journal:  Int J Telemed Appl       Date:  2017-11-09

Review 10.  ESR paper on the proper use of mobile devices in radiology.

Authors: 
Journal:  Insights Imaging       Date:  2018-03-22