Literature DB >> 23891101

Equivalent uniform dose for accelerated partial breast irradiation using the MammoSite applicator.

Alexandra J Stewart1, Jaroslaw T Hepel, Desmond A O'Farrell, Phillip M Devlin, Lori Lyn Price, Roger G Dale, David E Wazer.   

Abstract

INTRODUCTION: This study aims to quantify the radiobiology of the MammoSite applicator and examine whether there is a relationship between equivalent uniform dose (EUD) and radiotherapy-associated toxicity. METHODS AND MATERIALS: A previously-published version of the linear quadratic (LQ) model, designed to address the impact of dose-gradients in brachytherapy applications, was used to determine the biological effective dose (BED), equivalent dose in 2 Gray per fraction (EQD2) and EUD for the most common fractionation scheme for the MammoSite catheter (34 Gy in 10 fractions prescribed to 1cm from the balloon surface), using a range of balloon sizes in a series of patients treated with single or multiple dwell positions. Toxicity from the MammoSite catheter was assessed and statistical associations with the calculated EUDs were investigated.
RESULTS: The acute- and late-toxicity EUDs respectively range from 34.8-39.4 Gy and 33.4-37.6 Gy, with EUD decreasing as balloon diameter increases and/or the number of dwell positions increases. There was a positive association between EUD and hyperpigmentation and telangiectasia.
CONCLUSIONS: For APBI using the Mammosite applicator, EUD is higher than the marginal prescription dose and, for the dose-fractionation patterns considered here, was associated with acute and late skin toxicity. EUD is a potentially useful parameter to characterize non-uniform dose distributions related to brachytherapy treatments. Further evaluation in future studies is warranted.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Equivalent uniform dose; MammoSite catheter; Radiobiology; Toxicity analysis

Mesh:

Year:  2013        PMID: 23891101     DOI: 10.1016/j.radonc.2013.06.030

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  2 in total

1.  [Calculation of the equivalent uniform dose for accelerated partial breast irradiation using the MammoSite applicator].

Authors:  U Haverkamp; C Moustakis
Journal:  Strahlenther Onkol       Date:  2014-02       Impact factor: 3.621

2.  Use of a correlation analysis model in the optimization of intensity-modulated radiotherapy of prostate cancer.

Authors:  Xiadong Li; Qinghua Deng; Shenglin Ma; K E Zhang; Zhibing Wu; Jianjun Lai; Rongjun Tang; Yao Ren; Jiahao Wang; Lixia Xu
Journal:  Exp Ther Med       Date:  2015-10-26       Impact factor: 2.447

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.