Literature DB >> 23890209

Effect of clasp design on retention at different intervals using different abutment materials and in a simulated oral condition.

Mohamed A Helal1, Osama A Baraka, Mohamed E Sanad, Yasser Al-Khiary, Klaus Ludwig, Matthias Kern.   

Abstract

PURPOSE: The purpose of this study was to compare the retention of circlet (E) clasps and back-action clasps against three abutment surface materials during long-term simulation of attachment and detachment.
MATERIAL AND METHODS: Forty-eight test models were constructed by placing premolars (natural abutments or metal dies) inside metal blocks to test different abutment retention surface materials (sound enamel, composite resin, and glass-ceramic; 16 each). The models were duplicated into investment models for construction of circlet (E) and back-action clasps. Removal and insertion cycling of clasps was carried out for 250, 500, 1000, 2000, 4000, 8000, and 16,000 cycles. The retention of each clasp was measured before cycling and after each interval. Data were analyzed using 1-way-ANOVA, 2-way-ANOVA, and Mann-Whitney U tests.
RESULTS: No significant differences in retention of either clasp were found between the three abutment material surfaces; however, there was a significant decrease in retention force of the circlet (E) clasp between 1000 and 2000 cycles but not of the back-action clasp.
CONCLUSIONS: (1) The back-action clasp maintains its retention force for a longer period than the circlet (E) clasp. (2) Composite resin contouring of teeth provided retention comparable to enamel and a ceramic material.
© 2013 by the American College of Prosthodontists.

Entities:  

Keywords:  CAD/CAM; Clasp; ceramic; composite; enamel; retention

Mesh:

Substances:

Year:  2013        PMID: 23890209     DOI: 10.1111/jopr.12072

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  3 in total

1.  Impact of Nanoparticles Additions on the Strength of Dental Composite Resin.

Authors:  Emad Azmy; Mohamed Reda Zaki Al-Kholy; Mohamed Fattouh; Laila Mohamed Mohamed Kenawi; Mohamed Ahmed Helal
Journal:  Int J Biomater       Date:  2022-07-05

2.  Performance of Graphene-Based and Polyether-Ether-Ketone Polymers as Removable Partial Denture Esthetic Clasp Materials after Cyclic Fatigue.

Authors:  Mostafa Omran Hussein
Journal:  Polymers (Basel)       Date:  2022-07-23       Impact factor: 4.967

3.  Examination of inter-rater and intra-rater reliability during retentive force measurement of different clasps using the developed small-sized retentive force measurement device.

Authors:  Hitoshi Akiyama; Maiko Sakamoto; Ryoichi Akama; Jun Takei
Journal:  BMC Oral Health       Date:  2020-08-20       Impact factor: 2.757

  3 in total