Literature DB >> 23889829

Accuracy of ringless casting and accelerated wax-elimination technique: a comparative in vitro study.

Rahul Prasad1, Abdulaziz Abdullah Al-Keraif, Nidhi Kathuria, P V Gandhi, S V Bhide.   

Abstract

PURPOSE: The purpose of this study was to determine whether the ringless casting and accelerated wax-elimination techniques can be combined to offer a cost-effective, clinically acceptable, and time-saving alternative for fabricating single unit castings in fixed prosthodontics.
MATERIALS AND METHODS: Sixty standardized wax copings were fabricated on a type IV stone replica of a stainless steel die. The wax patterns were divided into four groups. The first group was cast using the ringless investment technique and conventional wax-elimination method; the second group was cast using the ringless investment technique and accelerated wax-elimination method; the third group was cast using the conventional metal ring investment technique and conventional wax-elimination method; the fourth group was cast using the metal ring investment technique and accelerated wax-elimination method. The vertical marginal gap was measured at four sites per specimen, using a digital optical microscope at 100× magnification. The results were analyzed using two-way ANOVA to determine statistical significance.
RESULTS: The vertical marginal gaps of castings fabricated using the ringless technique (76.98 ± 7.59 μm) were significantly less (p < 0.05) than those castings fabricated using the conventional metal ring technique (138.44 ± 28.59 μm); however, the vertical marginal gaps of the conventional (102.63 ± 36.12 μm) and accelerated wax-elimination (112.79 ± 38.34 μm) castings were not statistically significant (p > 0.05).
CONCLUSIONS: The ringless investment technique can produce castings with higher accuracy and can be favorably combined with the accelerated wax-elimination method as a vital alternative to the time-consuming conventional technique of casting restorations in fixed prosthodontics.
© 2013 by the American College of Prosthodontists.

Entities:  

Keywords:  Phosphate-bonded investments; alloys; copings; marginal gaps

Mesh:

Substances:

Year:  2013        PMID: 23889829     DOI: 10.1111/jopr.12082

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  2 in total

1.  An In Vitro Assessment of Marginal Accuracies in Copings Fabricated With Two Dissimilar Alloys: An Original Research Study.

Authors:  Prince Kumar; Nikhat Fatima; Ganesh Ramesh; Harsh Priyank; Ankita Shrivastav; Susovan Giri; Hiroj Bagde
Journal:  Cureus       Date:  2022-08-20

2.  Comparative Evaluation of Marginal Accuracy of Metal Copings Fabricated using Direct Metal Laser Sintering, Computer-Aided Milling, Ringless Casting, and Traditional Casting Techniques: An In vitro Study.

Authors:  Annu Eliza James; B Umamaheswari; C B Shanthana Lakshmi
Journal:  Contemp Clin Dent       Date:  2018 Jul-Sep
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.