Literature DB >> 23888877

Biomechanical comparison between bicortical pin and monocortical screw/polymethylmethacrylate constructs in the cadaveric canine cervical vertebral column.

Bianca F Hettlich1, Matthew J Allen, Daniel Pascetta, Geoffrey T Fosgate, Alan S Litsky.   

Abstract

OBJECTIVE: To compare biomechanical stiffness of cadaveric canine cervical spine constructs stabilized with bicortical stainless steel pins and polymethylmethacrylate (PMMA), monocortical stainless steel screws with PMMA, or monocortical titanium screws with PMMA. STUDY
DESIGN: Biomechanical cadaver study. ANIMALS: Eighteen canine cervical vertebral columns (C2-C7) were collected from skeletally mature dogs (weighing 22-32 kg).
METHODS: Specimens were radiographed and examined by dual energy X-ray absorptiometry. Stiffness of the unaltered C4-C5 intervertebral motion unit was measured in extension, flexion and lateral bending using non-destructive 4-point bend testing. Specimens were then stabilized by (1) bicortical stainless steel pins/PMMA, (2) monocortical stainless steel screws/PMMA, or (3) monocortical titanium screws/PMMA. Mechanical testing was repeated and stiffness data from unaltered specimens and the 3 treatment groups were compared.
RESULTS: All 3 surgical methods significantly increased stiffness of the C4-C5 motion unit compared with the unaltered specimen (P < .001 for all treatments), but stiffness was not significantly different among the 3 fixation groups (P = .578).
CONCLUSIONS: In this model, monocortical screw fixation (with stainless steel or titanium screws) was biomechanically equivalent to bicortical fixation. © Copyright 2013 by The American College of Veterinary Surgeons.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23888877     DOI: 10.1111/j.1532-950X.2013.12040.x

Source DB:  PubMed          Journal:  Vet Surg        ISSN: 0161-3499            Impact factor:   1.495


  2 in total

1.  Long-Term Follow-Up of Dogs and Cats after Stabilization of Thoracolumbar Instability Using 2-0 UniLock Implants.

Authors:  Julien Letesson; Bastien Goin; Jean Louis Trouillet; Paul Barthez
Journal:  Vet Med Int       Date:  2022-04-26

2.  Canine atlantoaxial optimal safe implantation corridors - description and validation of a novel 3D presurgical planning method using OsiriX™.

Authors:  Guillaume Leblond; Luis Gaitero; Noel M Moens; Alex Zur Linden; Fiona M K James; Gabrielle Monteith; John Runciman
Journal:  BMC Vet Res       Date:  2016-09-06       Impact factor: 2.741

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.