Literature DB >> 23888472

Volumetric breast density assessment: reproducibility in serial examinations and comparison with visual assessment.

J M Singh1, E M Fallenberg, F Diekmann, D M Renz, R Witlandt, U Bick, F Engelken.   

Abstract

BACKGROUND AND
PURPOSE: Mammographic breast density is the strongest known marker of breast cancer risk. Visual breast density assessment is subject to significant intra- and inter-rater variability. The aim of the present study was to test the reproducibility of automatic breast density assessment and to compare the results to the visual assessment. PATIENTS AND METHODS: Serial mammograms of 141 patients were retrospectively reviewed. Breast density was assessed both visually using a BI-RADS four-category breast density scale and with a software tool for volumetric breast density measurement.
RESULTS: The intra- and inter-rater reproducibility as well as inter-examination reproducibility were assessed for both techniques by calculating the intraclass correlation coefficient (ICC). The inter-examination reproducibility of the volumetric measurement of breast percent density was 0.91 (ICC; 95 % CI 0.87 - 0.93). There was no difference in the strength of the correlation between patients with a large vs. small difference in compression force. The intra- and inter-rater reproducibility ranged from 0.81 - 0.84 and 0.71 - 0.77, respectively. The inter-examination reproducibility of visual assessment was 0.75 - 0.81. The agreement of visual assessment with volumetric measurement was similar to the agreement among readers.
CONCLUSION: Our results indicate that volumetric breast density measurement provides higher reproducibility in serial examinations than visual assessment and may thus be preferable in the longitudinal assessment of breast density and in the measurement of breast density for risk stratification. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2013        PMID: 23888472     DOI: 10.1055/s-0033-1335981

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  5 in total

1.  Quantra™ should be considered a tool for two-grade scale mammographic breast density classification.

Authors:  Ernest U Ekpo; Mark F McEntee; Mary Rickard; Patrick C Brennan; Jyotsna Kunduri; Delgermaa Demchig; Claudia Mello-Thoms
Journal:  Br J Radiol       Date:  2016-02-16       Impact factor: 3.039

Review 2.  Measurement of breast density with digital breast tomosynthesis--a systematic review.

Authors:  E U Ekpo; M F McEntee
Journal:  Br J Radiol       Date:  2014-08-22       Impact factor: 3.039

3.  Automated mammographic density measurement using Quantra™: comparison with the Royal Australian and New Zealand College of Radiology synoptic scale.

Authors:  Inez Yeo; Judith Akwo; Ernest Ekpo
Journal:  J Med Imaging (Bellingham)       Date:  2020-05-29

4.  Comparison of Qualitative and Volumetric Assessments of Breast Density and Analyses of Breast Compression Parameters and Breast Volume of Women in Bahcesehir Mammography Screening Project.

Authors:  Ayşegül Akdoğan Gemici; Erkin Arıbal; Ayşe Nilüfer Özaydın; Sibel Özkan Gürdal; Beyza Özçınar; Neslihan Cabioğlu; Vahit Özmen
Journal:  Eur J Breast Health       Date:  2020-04-01

5.  Comparison of breast density assessments according to BI-RADS 4th and 5th editions and experience level.

Authors:  Aysegul Akdogan Gemici; Ersoy Bayram; Elif Hocaoglu; Ercan Inci
Journal:  Acta Radiol Open       Date:  2020-07-20
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.