Literature DB >> 23884838

MRI-guided stereotactic aspiration of brain abscesses by use of an optical tracking navigation system.

Yubo Lü1, Chengli Li, Ming Liu, Jan Fritz, John A Carrino, Lebin Wu, Bin Zhao.   

Abstract

BACKGROUND: Owing to the high risk of abscess drainage by craniotomy, imaging-guided stereotactic aspiration is considered an ideal choice in the management of brain abscesses. Interventional magnetic resonance imaging (MRI) represents a valuable technique for the treatment of brain abscess as a guiding modality.
PURPOSE: To evaluate the safety and efficacy of an interventional MRI system in performing the procedure.
MATERIAL AND METHODS: Thirteen brain abscesses in 11 patients were treated with percutaneous aspiration. All procedures were performed solely under the guidance of a 0.23-T open-configuration MRI scanner with optical tracking. Clinical and imaging follow-up was at 1 week, 1 month, 3 months, and 6 months. The changes of abscess, MRI features, and clinical symptoms were recorded. Procedure efficacy and safety were evaluated by success rate, procedure time, decrease of abscess, recovery rate, and complication. Descriptive statistical analysis was performed.
RESULTS: MRI-guided stereotactic aspirations were performed successfully in 13/13 (100%) abscesses. The mean operating time was 70 min (range, 45-100 min). Follow-up MRI at 1 week after the procedure showed average reduction of abscesses by 60% (2.1/3.5). And the abscesses continued to get smaller by up to 89.7% (3.14/3.5) at 1-month follow-up. All cavities resolved at the end of the 6-month follow-up period. The recovery rate was 100% for fever, headache, vomiting, papilledema, meningismus, altered sensorium, 75% (3/4) for hemiparesis, and 83.3% (5/6) for epilepsy. There were no complications.
CONCLUSION: Punctures of brain abscesses with subsequent aspiration can be performed safely and efficiently by monitoring the procedure using an open interventional MRI system.

Entities:  

Keywords:  Brain abscess; MR-guided; aspiration; interventional MRI

Mesh:

Substances:

Year:  2013        PMID: 23884838     DOI: 10.1177/0284185113493272

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  5 in total

1.  Combined magnetic resonance imaging and optical surgical navigation system guidance of percutaneous liver cryoablation in a porcine model.

Authors:  Kang Zhou; Zhuoli Zhang; Matteo Figini; Junjie Shangguan; Yining Wang; Haifeng Shi; Yumei Li; Zhengyu Jin; Jie Pan
Journal:  Am J Transl Res       Date:  2018-05-15       Impact factor: 4.060

2.  Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver.

Authors:  F Cornelis; H Takaki; M Laskhmanan; J C Durack; J P Erinjeri; G I Getrajdman; M Maybody; C T Sofocleous; S B Solomon; G Srimathveeravalli
Journal:  Cardiovasc Intervent Radiol       Date:  2014-11-07       Impact factor: 2.740

3.  Synchronization Design and Error Analysis of Near-Infrared Cameras in Surgical Navigation.

Authors:  Ken Cai; Rongqian Yang; Huazhou Chen; Yizhou Huang; Xiaoyan Wen; Wenhua Huang; Shanxing Ou
Journal:  J Med Syst       Date:  2015-10-29       Impact factor: 4.460

4.  Stereotactic aspiration combined with gamma knife radiosurgery for the treatment of cystic brainstem metastasis originating from lung adenosquamous carcinoma: A case report.

Authors:  Chao DU; Zhaohui Li; Zhijia Wang; Liping Wang; Y U Tian
Journal:  Oncol Lett       Date:  2015-02-16       Impact factor: 2.967

5.  A novel three-dimensional template combined with MR-guided 125I brachytherapy for recurrent glioblastoma.

Authors:  Xiangmeng He; Ming Liu; Menglong Zhang; Roberto Blanco Sequeiros; Yujun Xu; Ligang Wang; Chao Liu; Qingwen Wang; Kai Zhang; Chengli Li
Journal:  Radiat Oncol       Date:  2020-06-08       Impact factor: 3.481

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.