Physiologic mechanisms underlying the failure of the "shock index" as a tool for accurate assessment of patient status during progressive simulated hemorrhage.

Kristin Schafer1, Christina Van Sickle, Carmen Hinojosa-Laborde, Victor A Convertino.   

Abstract

BACKGROUND: Shock index (SI), the ratio of heart rate (HR) to systolic arterial pressure (SAP), is a metric often used to diagnose patients at risk of impending cardiovascular instability and hemorrhagic shock. We hypothesized that if SI reflected impending cardiovascular instability and shock in an individual, then: (1) elevations in SI and HR would be greater in individuals with low tolerance (LT) to progressive lower-body negative-pressure (LBNP) compared with individuals with high tolerance (HT), and (2) LT would be associated with greater vagal withdrawal of the baroreflex sensitivity (BRS) compared with HT.
METHODS: A total of 187 healthy subjects (HT, 125; LT, 62) underwent exposure to LBNP until a SAP of less than 80 mm Hg (instability) was achieved. HR and SAP were used to calculate SI, and BRS was determined from spontaneous fluctuations in R-R interval and diastolic arterial pressure. Maximal cardiac vagal withdrawal was calculated as the difference between BRS at baseline and BRS at 100% LBNP tolerance.
RESULTS: Contrary to our hypothesis, SI at 60%, 80%, and 100% LBNP tolerance in LT (0.59 ± 0.03, 0.73 ± 0.04, and 0.97 ± 0.06, respectively) was lower (p ≤ 0.002) than SI in HT subjects at the same levels (0.66 ± 0.03, 0.84 ± 0.04, and 1.24 ± 0.06, respectively). Maximal cardiac vagal withdrawal was less (p = 0.045) in LT subjects (11.3 ± 2.2 ms/mm Hg) compared with HT subjects (14.9 ± 2.5 ms/mm Hg). The sensitivity of SI in identifying impending instability (SI, 0.9) at 80% and 100% LBNP tolerance was 13% and 63% in LT subjects and 34% and 91% in HT subjects, respectively.
CONCLUSION: The low sensitivity of the SI observed in LT individuals is associated with a lower capacity to withdraw cardiac vagal activity and can lead to an undertriage of those patients most likely to develop early hemorrhagic shock.

Entities:  

Mesh:

Year:  2013        PMID: 23883908     DOI: 10.1097/TA.0b013e31829b73aa

Source DB:  PubMed          Journal:  J Trauma Acute Care Surg        ISSN: 2163-0755            Impact factor:   3.313


  4 in total

1.  Reductions in central venous pressure by lower body negative pressure or blood loss elicit similar hemodynamic responses.

Authors:  Blair D Johnson; Noud van Helmond; Timothy B Curry; Camille M van Buskirk; Victor A Convertino; Michael J Joyner
Journal:  J Appl Physiol (1985)       Date:  2014-05-29

2.  Shock index: blunt clinical predictions.

Authors:  Boning Li; Christine Fanning; Amit Patel; Amay Parikh
Journal:  Crit Care       Date:  2013-11-21       Impact factor: 9.097

3.  Resting sympathetic baroreflex sensitivity in subjects with low and high tolerance to central hypovolemia induced by lower body negative pressure.

Authors:  Carmen Hinojosa-Laborde; Kathy L Ryan; Caroline A Rickards; Victor A Convertino
Journal:  Front Physiol       Date:  2014-06-30       Impact factor: 4.566

4.  Effect of hemorrhage rate on early hemodynamic responses in conscious sheep.

Authors:  Christopher G Scully; Chathuri Daluwatte; Nicole R Marques; Muzna Khan; Michael Salter; Jordan Wolf; Christina Nelson; John Salsbury; Perenlei Enkhbaatar; Michael Kinsky; George C Kramer; David G Strauss
Journal:  Physiol Rep       Date:  2016-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.