| Literature DB >> 2388327 |
B Rossman1, M Mieza, A Melman.
Abstract
Dynamic cavernosometry and cavernosography can be used to identify patients with corporeal venous incompetence as a cause of erectile dysfunction. We reviewed our series of 16 patients with venous leakage who underwent surgical correction of the specific abnormality identified on cavernosography. Short-term and long-term results were obtained, and while at least temporary improvement was noted in 89.5% of the patients the long-term results tended to show a reversion to the preoperative status in the majority.Entities:
Mesh:
Year: 1990 PMID: 2388327 DOI: 10.1016/s0022-5347(17)39553-8
Source DB: PubMed Journal: J Urol ISSN: 0022-5347 Impact factor: 7.450