Elisabeth J Faassen1, Miquel Lürling. 1. Aquatic Ecology & Water Quality Management Group, Wageningen University, PO Box 47, Wageningen 6700 AA, The Netherlands. els.faassen@wur.nl
Abstract
Microcystins (MCs) are the most frequently found cyanobacterial toxins in freshwater systems. Many MC variants have been identified and variants differ in their toxicity. Recent studies showed that the variants MC-LW and MC-LF might be more toxic than MC-LR, the variant that is most abundant and mostly used for risk assessments. As little is known about the presence of these two variants in The Netherlands, we determined their occurrence by analyzing 88 water samples and 10 scum samples for eight MC variants ((dm-7-)MC-RR, MC-YR, (dm-7-)MC-LR, MC-LY, MC-LW and MC-LF) by liquid chromatography with tandem mass spectrometry detection. All analyzed MC variants were detected, and MC-LW and/or MC-LF were present in 32% of the MC containing water samples. When MC-LW and MC-LF were present, they contributed to nearly 10% of the total MC concentrations, but due to their suspected high toxicity, their average contribution to the total MC toxicity was estimated to be at least 45%. Given the frequent occurrence and possible high toxicity of MC-LW and MC-LF, it seems better to base health risk assessments on the toxicity contributions of different MC variants than on MC-LR concentrations alone.
Microcystins (MCs) are the most frequently found cyanobacterial toxins in freshwater systems. Many MC variants have been identified and variants differ in their toxicity. Recent studies showed that the variants MC-LW and MC-LF might be more toxic than MC-LR, the variant that is most abundant and mostly used for risk assessments. As little is known about the presence of these two variants in The Netherlands, we determined their occurrence by analyzing 88 water samples and 10 scum samples for eight MC variants ((dm-7-)MC-RR, MC-YR, (dm-7-)MC-LR, MC-LY, MC-LW and MC-LF) by liquid chromatography with tandem mass spectrometry detection. All analyzed MC variants were detected, and MC-LW and/or MC-LF were present in 32% of the MC containing water samples. When MC-LW and MC-LF were present, they contributed to nearly 10% of the total MC concentrations, but due to their suspected high toxicity, their average contribution to the total MCtoxicity was estimated to be at least 45%. Given the frequent occurrence and possible high toxicity of MC-LW and MC-LF, it seems better to base health risk assessments on the toxicity contributions of different MC variants than on MC-LR concentrations alone.
The incidence and intensity of cyanobacterial blooms are on the rise worldwide [1,2]. Cyanobacterial blooms present a serious health threat because cyanobacteria might produce potent toxins [3] of which microcystins (MCs) are most frequently encountered in freshwater blooms all around the world [4]. MCs are non-ribosomally synthesized cyclic heptapeptides with a size between 909 and 1115 Da [4,5]. Their general structure is cyclo(-d-ala-l-X-erythro-β-d-methylaspartic acid-l-Y-Adda-d-isoglutamic acid-N-methyldehydroalanine), where Adda is (2S,3S,8S,9S)-3-amino-9-methoxy-2,6,8-trimethyl-10-phenyldeca-4,6-dienoic acid and X and Y are variable l-amino acids [6] (Figure 1).
Figure 1
General structure of microcystins and examples of substitutions at position X and Y resulting in the variants MC-RR, MC-LR, MC-LW and MC-LF if positions R1 and R2 are methylated.
General structure of microcystins and examples of substitutions at position X and Y resulting in the variants MC-RR, MC-LR, MC-LW and MC-LF if positions R1 and R2 are methylated.MCs are potent inhibitors of protein phosphatases and they primary cause liver damage, although other organs can also be affected [7]. Furthermore, MCs are tumor promoters [7,8]. The toxicity of different variants when administered by intraperitoneal injection (i.p.) to mice varies substantially. MC-LR is the most toxic variant and replacement of the hydrophobic leucine (L) in position X with a more hydrophilic amino acid (e.g., arginine, R) reduces toxicity [8]. No mousetoxicity data are available for MC-LW and MC-LF, but recent in vitro studies show that these variants, in which the hydrophobic amino acids tryptophan (W) or phenylalanine (F) occupy position Y, were distinctly more toxic than MC-LR. They were more cytotoxic than MC-LR to human hepatocytes, organic anion transporting polypeptide (OATP)-transfected embryonic kidney cells and Caco-2 cells [9,10] and also to primary murine whole brain cells [11]. Also when other endpoints were used, like tau phosphorylation and neurite length of murine neurons [12], proliferation and morphology of humanCaco-2 cells [10] and growth inhibition in humanOATP-transfected HeLa cells [13], MC-LW and MC-LF were distinctly more toxic than MC-LR. Because MC-LW and MC-LF were approximately equally strong protein phosphatase inhibitors as MC-LR [9,10,13], their enhanced toxicity can probably be attributed to the greater ability of these variants to enter cells, either because of variant dependent OATP mediated transport [14] or because of differences in the interaction with membranes [15]. MC-LW and MC-LF were also more toxic to the protozoan Tetrahymena pyriformis than MC-LR [16], although this effect was less pronounced than in the in vitro studies (Table 1).
Table 1
Relative toxicity of seven microcystin variants to MC-LR based on different endpoints, higher numbers indicate higher toxicity. i.p.: Intraperitoneal injection; dm-7: demethylated at position R2; n.d.: Not determined.
MC variant
LD50 mouse (i.p.) [8]
LC50 protozoan [16]
EC50in vitro1 [9]
Factor used in this study
dm-7-MC-RR
0.28
n.d.
n.d.
0.28
MC-RR
0.06–0.10
n.d.
0.02–0.20
0.08
MC-YR
0.25–0.33
n.d.
n.d.
0.29
dm-7-MC-LR
0.20
n.d.
n.d.
0.20
MC-LY
0.56
1.1–1.4
n.d.
0.56
MC-LW
n.d.
1.9–2.9
7–64
7
MC-LF
n.d.
2.0–3.0
7–69
7
1 Based on the cytotoxicity to human primary hepatocytes and OATP-transfected human embryonic kidney cells.
Relative toxicity of seven microcystin variants to MC-LR based on different endpoints, higher numbers indicate higher toxicity. i.p.: Intraperitoneal injection; dm-7: demethylated at position R2; n.d.: Not determined.1 Based on the cytotoxicity to human primary hepatocytes and OATP-transfected human embryonic kidney cells.Few reports exist on the occurrence of MC-LW and MC-LF in environmental samples. MC-LR is one of the most frequently observed MCs in the environment along with the variants MC-RR and MC-YR [4]. However, when looked for, MC-LW and MC-LF have also been detected [17,18,19,20,21,22,23,24,25,26], albeit not in all cases (e.g., [27,28,29]). Despite the potential higher toxicity of MC-LW and MC-LF, risk assessments are often based on MC-LR or MC-LR equivalents, and only sometimes on total MC or MC-LRtoxicity equivalents [30].In The Netherlands, MCs are the most abundant cyanotoxins, but little information exists on the occurrence of different variants, as most MC analyses have been performed by ELISA. Occasionally, some environmental samples have been analyzed by high-performance liquid chromatography with photodiode array detection but only for the variants MC-LR, MC-RR and MC-YR [31]. However, recently we showed that considerable amounts of the variants MC-LW and MC-LF were present in cyanobacterial material from a case of dog fatalities in The Netherlands [25]. The aim of the current research was therefore to determine the occurrence of MC-LW and MC-LF in Dutch surface waters and to estimate their contribution to the total MCtoxicity. For this, 88 water samples and 10 scum samples from 86 sites in The Netherlands (Figure 2) were analyzed for eight MC-variants and nodularin by liquid chromatography with tandem mass spectrometry detection (LC-MS/MS).
Figure 2
Sampling sites in the Netherlands.
Sampling sites in the Netherlands.
2. Results and Discussion
Microcystins were detected in 77 out of 88 water samples analyzed. In four samples MCs were present only at trace levels, but in 73 samples in sufficient amounts to allow quantification (Table 2). MC-LR was the most frequently encountered variant being present in 85% of the samples, followed by MC-YR (82%), dm-7-MC-LR (81%), MC-RR (78%) and dm-7-MC-RR (66%). MC-LY (28%), MC-LW (23%) and MC-LF (26%) were less frequently detected and mostly occurred together (Supplementary Table S1 and Table 2). Microcystis aeruginosa or M. flos-aquae were dominantly present in all but one location where MC-LW and MC-LF were detected. The other location where MC-LF was present was dominated by Woronichinia naegeliana and Anabaena flos-aquae (Supplementary Table S1). MC-LR, dm-7-MC-LR, MC-YR and MC-RR were also most frequently present in the cyanobacterial scums as they were detected in each sample. dm-7-MC-RR was detected in eight of the 10 samples and MC-LY, MC-LW and MC-LF were again less frequently detected, they were encountered in four of the 10 samples (Table 3). Also, in the scums, MC-LY, MC-LW and MC-LF were mostly detected together and they were detected at locations where either M. aeruginosa, W. naegeliana or A. flos-aquae was present (Supplementary Table S2).
Table 2
Microcystin (MC) concentrations (μg/L) detected in 88 water samples, summarized from Supplementary Table S1. Nodularin was not detected.
dm-7-RR
RR
YR
dm-7-LR
LR
LY
LW
LF
Total MC
average
0.45
5.0
2.4
4.0
35
5.9
14
4.2
49
median
0.20
0.81
0.23
0.12
1.3
0.35
0.61
0.42
2.5
maximum
3.6
66
41
220
2100
110
260
33
2800
minimum
0.03
0.02
0.01
0.003
0.01
0.001
0.05
0.05
0.02
n quantified
38
67
67
62
73
25
20
17
73
n not quantified
20
2
5
9
2
0
0
6
4
n not detected
30
19
16
17
13
63
68
65
11
Table 3
Microcystin (MC) concentrations (μg/L) detected in 10 scum samples, summarized from Supplementary Table S2. Nodularin was not detected.
dm-7-RR
RR
YR
dm-7-LR
LR
LY
LW
LF
Total MC
average
47
780
230
41
1700
840
300
580
3400
median
11
85
81
7.6
160
530
100
260
480
maximum
170
4600
1200
230
7900
2300
990
1800
14,000
minimum
4.3
3.8
1.2
0.89
3.0
24
10
8.0
26
n detected
8
10
10
10
10
4
4
4
10
n not detected
2
0
0
0
0
6
6
6
0
Microcystin (MC) concentrations (μg/L) detected in 88 water samples, summarized from Supplementary Table S1. Nodularin was not detected.Microcystin (MC) concentrations (μg/L) detected in 10 scum samples, summarized from Supplementary Table S2. Nodularin was not detected.These results confirm that MC-LR, MC-RR and MC-YR are in general more abundant than MC-LY, MC-LW and MC-LF (e.g., [18,20,26]). In our study, MC-LW and/or MC-LF were detected in 25 of the 77 water samples that contained MCs, which means they were present in 32% of the MC-containing samples. This is considerably more than the limited presence of MC-LF and MC-LW found in some studies [20,26], but less than the 45% found in lakes and reservoirs in the United States [18] and the 89% found in a Turkish lake [23]. Also in the American lakes, MC-LY, MC-LW and MC-LF mostly co-occurred, but this was not the case in the Turkish study.The maximum concentration of total MCs in the water samples was 2800 μg/L, and in two scum samples concentrations above 13,000 μg/L were detected (Table 2, Table 3). MC-LR was on average present in the highest concentrations in the water samples, dm-7-MC-RR had on average the lowest concentrations (Table 2, Figure 3). In water samples where MC-LW and MC-LF were present, MC-LW contributed on average 5.2% to the total MC concentration and MC-LF contributed 4.6%. This is slightly higher than the values found in other field samples [17,18]. However, higher relative MC-LW and MC-LF concentrations have been reported from M. aeruginosa culture strains, e.g., 21% LW and 19% LF in PCC7820 [32] and 19% LW and 14% LF in AB2005/45 [33]. Those values match with the highest contributions found in our field survey; in the location Borne—t’Dijkhuis, MC-LW contributed for 14% to the total MC-pool, while a 14% contribution of MC-LF was found at Huizen—Gooihoofd (Supplementary Table S1). Thus, the MC variants MC-LW and MC-LF can make up a significant part of the total MC-pool. In one study, extracellular MC-LW was even present at a concentration of 99 μg/L, thereby making up 96% of the total dissolved MC pool in that sample [23].
Figure 3
Concentrations of eight different microcystin (MC) variants (μg/L) in 88 water samples from different sites in The Netherlands. Only values above quantification limit are included. Boundaries of the boxes indicate the 25th and 75th percentiles, lines within boxes mark the median, whiskers indicate the 10th and 90th percentiles, dots represent the 5th and 95th percentiles.
Concentrations of eight different microcystin (MC) variants (μg/L) in 88 water samples from different sites in The Netherlands. Only values above quantification limit are included. Boundaries of the boxes indicate the 25th and 75th percentiles, lines within boxes mark the median, whiskers indicate the 10th and 90th percentiles, dots represent the 5th and 95th percentiles.The contribution of each variant to the overall MCtoxicity of a sample was determined by assigning a toxicity factor to each variant (Table 1) and by multiplying variant concentrations by these toxicity factors. Toxicity factors for dm-7-MC-RR, MC-RR, MC-YR, dm-7-MC-LR and MC-LY were estimated from the average i.p. LD50 values to mice as given in Zurawell et al. (2005) [8]. For MC-LW and MC-LF, the lowest reported in vitro toxicity factor to primary human hepatocytes was used [9]. The estimated toxicity contribution of MC-LW and MC-LF in the 21 samples, where these variants were detected above the quantification level, are shown in Figure 4. MC-LW and MC-LF significantly contribute to the overall MCtoxicity when they are present; on average 45% of the total MCtoxicity is caused by these two variants. It should be noted that these toxicity contributions are estimates and should therefore be interpreted with caution. For six variants, in vivo toxicity factors are used, while the contribution of MC-LW and MC-LF was estimated by in vitro toxicity factors. It is however unknown whether higher in vitro toxicity also results in higher in vivo toxicity, as little is known about the toxicokinetics and therefore the bioavailability of the latter variants. It is for instance not known whether MC-LW and MC-LF are stable in the stomach [15]. However, for other variants (MC-RR and MC-LR), comparison of in vivo and in vitro toxicity data resulted in comparable toxicity factors ([9], Table 1). Also, MC-LW and MC-LF were more toxic than MC-LR to the protozoan Tetrahymena pyriformis [16], so it is likely that the enhanced toxicity of MC-LW and MC-LF that was observed in vitro will also result in a higher toxicity in vivo.
Figure 4
Estimated contribution of MC-LW and MC-LF to the total microcystin (MC) toxicity in 21 surface water samples with cyanobacterial presence.
The total toxicity of the samples has only been based on the contribution of the eight MC variants that have been analyzed in this study. As dozens of MC variants have been reported [8] and individual cyanobacterial strains can produce many variants (e.g., [33]), the total toxicity of the samples is likely underestimated. Furthermore, we cannot exclude the possibility that structural isomers, which sometimes exhibit different toxicities [8], have attributed to the signal of some of the eight MC variants analyzed in this study. Nevertheless, our analysis shows that MC-LW and MC-LF are likely to significantly contribute to the total MCtoxicity when they are present.Estimated contribution of MC-LW and MC-LF to the total microcystin (MC) toxicity in 21 surface water samples with cyanobacterial presence.As it has become clear that MC-LW and MC-LF are regularly present in MC containing blooms and that their contribution to the total MCtoxicity of these blooms can be substantial, it seems that risk assessment can better be based on the toxicity contributions of all MC variants than only on concentrations of MC-LR, as the first would be a better reflection of the health risk. To assess this risk, concentrations of individual MC variants should be analyzed. However, analytical methods that can identify different variants, such as LC-MS/MS operated in multiple reaction monitoring mode, have the disadvantage of potentially missing variants. Complementary to these methods, total MC concentrations could therefore be determined, for instance by Adda-based ELISA. In this way it can be checked whether the most abundant variants have indeed been identified. For The Netherlands, this would mean that the frequent use of ELISA for determination of MC concentrations should be complemented by analytical methods that can distinguish individual variants.
3. Experimental Section
3.1. Sample Origin
Samples were collected from 86 fresh surface waters in The Netherlands from 2009 to 2012. All samples were taken in the months July, August, September and October. Locations differed in their morphology from small urban ponds to bigger lakes and sheltered beaches at river banks. Water samples were collected in a polyethylene bottle, scum samples were collected in a small plastic cup. All samples were processed within 24 h of collection.
3.2. Sample Extraction
Cyanobacterial species in the samples were identified by light microscopy. Of the water samples, 50 to 250 mL was glass-fiber filtered (GF/C, Whatman International Ltd., Maidstone, UK) and stored at −20 °C. Of each scum sample, 1 mL was filtered over a GF/C filter and also these filters were stored at −20 °C. Before extraction, filters were transferred to 8 mL glass tubes and placed for two hours in a freeze-drier (Alpha 1-2 LD, Martin Christ Gefriertrocknungsanlagen GmbH, Osterode am Harz, Germany). Subsequently, MCs were extracted three times at 60 °C in 2.5 mL 75% methanol–25% Millipore water (v/v). Extracts were dried in a Speedvac (Savant SPD121P, Thermo Scientific, Waltham, MA, USA) and reconstituted in 900 μL methanol. The reconstituted samples were transferred to 2 mL Eppendorf vials with a cellulose-acetate filter (0.2 μm, Grace Davison Discovery Sciences, Deerfield, IL, USA) and centrifuged for 5 min at 16,000× g (Galaxy 16DH, VWR, International, Buffalo Grove, IL, USA). Filtrates were transferred to amber glass vials for LC-MS/MS analysis. If needed, samples with high MC concentrations were diluted in methanol before re-analysis.
3.3. LC-MS/MS Analysis
Samples were analyzed for eight MC variants (dm-7-MC-RR, MC-RR, MC-YR, dm-7-MC-LR, MC-LR, MC-LY, MC-LW and MC-LF) and nodularin (NOD) by LC-MS/MS as described in [25]. LC-MS/MS analysis was performed on an Agilent 1200 LC and an Agilent 6410A QQQ. The compounds were separated on an Agilent Eclipse XDB-C18 4.6 × 150 mm, 5 μm column by Millipore water with 0.1% formic acid (v/v, eluent A) and acetonitrile with 0.1% formic acid (v/v, eluent B). Elution program was 0–2 min 30% B, 6–12 min 90% B, with a linear increase of B between 2 and 6 min and a 5 min post run at 30% B. Injection volume was 10 μL, flow 0.5 mL/min, column temperature was 40 °C. The LC-MS/MS was operated in positive mode with an electrospray ionisation source, nitrogen was used as drying and collision gas. For each compound, two transitions were monitored in MRM mode. The first quadrupole was operated in unit mode, the second quadrupole was operated in widest mode. Dwell time was 50 ms. MS/MS settings for each compound are shown in Table 4. Calibration standards were obtained from DHI LAB Products (Hørsholm, Denmark) and prepared in methanol, samples were quantified against a calibration curve and subsequently corrected for recovery. Each sample was injected once.
Table 4
MS/MS settings for microcystin (MC) and nodularin (NOD) analysis.
Compound
Retention time
Precursor ion
Fragmentor
Quantifier ion
CE 1 quantifier
Qualifier ion
CE 1 qualifier
Ratio 2
min
m/z
V
m/z
V
m/z
V
%
dm-7-MC-RR
6.93
512.8
135
135.1
26
70.1
85
1.2
MC-RR
7.62
519.8
151
135.1
30
70.1
75
2.7
NOD
8.03
825.5
220
135.1
70
70.1
95
44.2
MC-YR
8.16
523.3
102
911.5
5
135.1
6
103.6
dm-7-MC-LR
8.21
491.3
88
847.6
5
135.1
6
84.0
MC-LR
8.24
498.3
88
135.1
6
482.3
6
56.7
MC-LY
9.67
868.4
170
163.0
35
136.1
75
29.0
MC-LW
10.22
891.5
146
163.0
31
159.0
75
26.9
MC-LF
10.47
852.5
140
163.1
31
120.1
79
39.1
1 Collision energy; 2 Ratio between abundance of the qualifier and quantifier ion.
Information on recovery, repeatability, limit of detection and limit of quantification of the analysis is given in [25]. Chromatograms of a calibration standard and a sample are shown in Figure S1.MS/MS settings for microcystin (MC) and nodularin (NOD) analysis.1 Collision energy; 2 Ratio between abundance of the qualifier and quantifier ion.
4. Conclusions
The MC variants MC-LW and MC-LF were present in 32% of the MC-containing Dutch water samples. When present, these variants contributed on average to nearly 10% of the total MC concentration, but due to their suspected higher toxicity, their average contribution to overall MCtoxicity of the samples was estimated to be at least 45%. Given this frequent occurrence and possible high toxicity, it seems better to base health risk estimations on the toxicity contributions of different MC variants than on MC-LR concentrations as is common practice in many countries [30].
Authors: Daniel Feurstein; Kerstin Stemmer; Julia Kleinteich; Tobias Speicher; Daniel R Dietrich Journal: Toxicol Sci Date: 2011-09-20 Impact factor: 4.849
Authors: Ronald W Zurawell; Huirong Chen; Janice M Burke; Ellie E Prepas Journal: J Toxicol Environ Health B Crit Rev Date: 2005 Jan-Feb Impact factor: 6.393
Authors: Dedmer B Van de Waal; Jolanda M H Verspagen; Miquel Lürling; Ellen Van Donk; Petra M Visser; Jef Huisman Journal: Ecol Lett Date: 2009-09-15 Impact factor: 9.492
Authors: Daniel Jančula; Lucie Straková; Jan Sadílek; Blahoslav Maršálek; Pavel Babica Journal: Environ Sci Pollut Res Int Date: 2014-03-23 Impact factor: 4.223