Literature DB >> 23880544

Computational assessment of deep-seated tumor treatment capability of the 9Be(d,n)10B reaction for accelerator-based boron neutron capture therapy (AB-BNCT).

M E Capoulat1, D M Minsky2, A J Kreiner2.   

Abstract

The 9Be(d,n)10B reaction was studied as an epithermal neutron source for brain tumor treatment through Boron Neutron Capture Therapy (BNCT). In BNCT, neutrons are classified according to their energies as thermal (<0.5 eV), epithermal (from 0.5 eV to 10 keV) or fast (>10 keV). For deep-seated tumors epithermal neutrons are needed. Since a fraction of the neutrons produced by this reaction are quite fast (up to 5-6 MeV, even for low-bombarding energies), an efficient beam shaping design is required. This task was carried out (1) by selecting the combinations of bombarding energy and target thickness that minimize the highest-energy neutron production; and (2) by the appropriate choice of the Beam Shaping Assembly (BSA) geometry, for each of the combinations found in (1). The BSA geometry was determined as the configuration that maximized the dose deliverable to the tumor in a 1 h treatment, within the constraints imposed by the healthy tissue dose adopted tolerance. Doses were calculated through the MCNP code. The highest dose deliverable to the tumor was found for an 8 μm target and a deuteron beam of 1.45 MeV. Tumor weighted doses ≥40 Gy can be delivered up to about 5 cm in depth, with a maximum value of 51 Gy at a depth of about 2 cm. This dose performance can be improved by relaxing the treatment time constraint and splitting the treatment into two 1-h sessions. These good treatment capabilities strengthen the prospects for a potential use of this reaction in BNCT.
Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  (9)Be(d,n)(10)B reaction; Accelerator-based BNCT; Brain tumor treatment; Monte-Carlo-simulations

Mesh:

Substances:

Year:  2013        PMID: 23880544     DOI: 10.1016/j.ejmp.2013.07.001

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  2 in total

Review 1.  Physical, dosimetric and clinical aspects and delivery systems in neutron capture therapy.

Authors:  Bagher Farhood; Hadi Samadian; Mahdi Ghorbani; Seyed Salman Zakariaee; Courtney Knaup
Journal:  Rep Pract Oncol Radiother       Date:  2018-08-01

2.  Present status of Accelerator-Based BNCT.

Authors:  Andres Juan Kreiner; Javier Bergueiro; Daniel Cartelli; Matias Baldo; Walter Castell; Javier Gomez Asoia; Javier Padulo; Juan Carlos Suárez Sandín; Marcelo Igarzabal; Julian Erhardt; Daniel Mercuri; Alejandro A Valda; Daniel M Minsky; Mario E Debray; Hector R Somacal; María Eugenia Capoulat; María S Herrera; Mariela F Del Grosso; Leonardo Gagetti; Manuel Suarez Anzorena; Nicolas Canepa; Nicolas Real; Marcelo Gun; Hernán Tacca
Journal:  Rep Pract Oncol Radiother       Date:  2014-12-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.