Literature DB >> 23880276

The incidence of root microcracks caused by 3 different single-file systems versus the ProTaper system.

Rui Liu1, Ben Xiang Hou, Paul R Wesselink, Min-Kai Wu, Hagay Shemesh.   

Abstract

INTRODUCTION: The aim of this study was to compare the incidence of root cracks observed at the apical root surface and/or in the canal wall after canal instrumentation with 3 single-file systems and the ProTaper system (Dentsply Maillefer, Ballaigues, Switzerland).
METHODS: One hundred mandibular incisors were selected. Twenty control teeth were coronally flared with Gates-Glidden drills (Dentsply Maillefer). No further preparation was made. The other 80 teeth were mounted in resin blocks with simulated periodontal ligaments, and the apex was exposed. They were divided into 4 experimental groups (n = 20); the root canals were first coronally flared with Gates-Glidden drills and then instrumented to the full working length with the ProTaper, OneShape (Micro-Mega, Besancon, France), Reciproc (VDW, Munich, Germany), or the Self-Adjusting File (ReDent-Nova, Ra'anana, Israel). The apical root surface and horizontal sections 2, 4, and 6 mm from the apex were observed under a microscope. The presence of cracks was noted. The chi-square test was performed to compare the appearance of cracked roots between the experimental groups.
RESULTS: No cracks were found in the control teeth and teeth instrumented with the Self-Adjusting File. Cracks were found in 10 of 20 (50%), 7 of 20 (35%), and 1 of 20 (5%) teeth after canal instrumentation with the ProTaper, OneShape, and Reciproc files, respectively. The difference between the experimental groups was statistically significant (P < .001).
CONCLUSIONS: Nickel-titanium instruments may cause cracks on the apical root surface or in the canal wall; the Self-Adjusting File and Reciproc files caused less cracks than the ProTaper and OneShape files.
Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Root crack; single-file system

Mesh:

Substances:

Year:  2013        PMID: 23880276     DOI: 10.1016/j.joen.2013.04.013

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  40 in total

1.  "Dentinal microcracks after root canal preparation" a comparative evaluation with hand, rotary and reciprocating instrumentation.

Authors:  N Tulasi Priya; Veeramachaneni Chandrasekhar; S Anita; Muralidhar Tummala; T B Phanindhar Raj; Vijetha Badami; Pradeep Kumar; E Soujanya
Journal:  J Clin Diagn Res       Date:  2014-12-05

2.  Incidence of microcracks in maxillary first premolars after instrumentation with three different mechanized file systems: a comparative ex vivo study.

Authors:  A Kfir; D Elkes; A Pawar; A Weissman; I Tsesis
Journal:  Clin Oral Investig       Date:  2016-03-30       Impact factor: 3.573

Review 3.  Root dentine and endodontic instrumentation: cutting edge microscopic imaging.

Authors:  Amre R Atmeh; Timothy F Watson
Journal:  Interface Focus       Date:  2016-06-06       Impact factor: 3.906

4.  Dentinal microcracks induced by endodontic procedures: A scientometric and bibliometric analysis.

Authors:  Stéphanie Quadros Tonelli; Kênia Soares de Toubes; André Maués Brabo Pereira; Antônio Carlos de Oliveira Miranda; Letícia Ladeia Fernandes; Eduardo Nunes; Frank Ferreira Silveira
Journal:  J Conserv Dent       Date:  2022-05-02

5.  Evaluation of apical root defects during canal instrumentation with two different nickel-titanium (NiTi) systems by optical coherence tomography (OCT) scan.

Authors:  Chen Chen; Wenxin Zhang; Yuhong Liang
Journal:  J Dent Sci       Date:  2021-10-23       Impact factor: 3.719

6.  Imaging of root canal treatment using ultra high field 9.4T UTE-MRI - a preliminary study.

Authors:  Maximilian Timme; Max Masthoff; Nina Nagelmann; Malte Masthoff; Cornelius Faber; Sebastian Bürklein
Journal:  Dentomaxillofac Radiol       Date:  2019-09-23       Impact factor: 2.419

7.  The effects of different nickel-titanium instruments on dentinal microcrack formations during root canal preparation.

Authors:  Yakup Ustun; Tugrul Aslan; Burak Sagsen; Bertan Kesim
Journal:  Eur J Dent       Date:  2015 Jan-Mar

8.  Fracture resistance exhibited by endodontically treated and retreated teeth shaped by ProTaper NEXT versus WaveOne: An in vitro study.

Authors:  Neha Deepak Khalap; Vibha Hegde; Sharad Kokate
Journal:  J Conserv Dent       Date:  2015 Nov-Dec

9.  Stereomicroscopic evaluation of dentinal defects induced by new rotary system: "ProTaper NEXT".

Authors:  Deepa Deepak Shori; Pratima Ramakrishna Shenoi; Arshia R Baig; Rajesh Kubde; Chetana Makade; Swapnil Pandey
Journal:  J Conserv Dent       Date:  2015 May-Jun

10.  Fracture strength of roots instrumented with three different single file systems in curved root canals.

Authors:  Bilge Gulsum Nur; Evren Ok; Mustafa Altunsoy; Mehmet Tanriver; Ismail Davut Capar
Journal:  Eur J Dent       Date:  2015 Apr-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.