PURPOSE: The purpose of the present preliminary in vitro study on bovine ribs was to validate a new intraoperative site-specific classification of bone Density Index (IDI), obtained by an innovative computerized implant motor, by correlating these data with the data obtained by the histomorphometrical evaluation of the same samples.
MATERIALS AND METHODS: Five segments of bovine ribs were used, and a total of 22 perforations were performed. A computerized implant motor ("Torque Measuring Motor") was used to evaluate the bone density, which was classified into four classes: ID1, ID2, ID3, and ID4. Histomorphometrical analysis of bone density, expressed as percentage of bony trabeculae over the total biopsy area, was also performed. The data of bone density obtained by the implant motor were statistically correlated with the histomorphometrical results.
RESULTS: A significant positive correlation was found between the bone density measured by the implant motor and the bone density assessed by histomorphometry (r = 0.89, p < .0001). Moreover, a significant positive correlation in D1, D2, and D4, whereas a negative, not significant correlation in D3 was found.
CONCLUSION: Within the limitations of this in vitro study, the intraoperative site-specific classification of bone density, obtained with this innovative system, could be helpful for the clinician to tailor the surgical protocol to the different situations in implant dentistry.
© 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  bone density; bovine ribs; histomorphometry; implant; implant stability quotient; in vitro study; insertion torque; primary stability; resonance frequency analysis

Mesh:

Year:  2013        PMID: 23879771     DOI: 10.1111/cid.12121

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  11 in total

1.  A torque-measuring micromotor provides operator independent measurements marking four different density areas in maxillae.

Authors:  Danilo Alessio Di Stefano; Paolo Arosio; Adriano Piattelli; Vittoria Perrotti; Giovanna Iezzi
Journal:  J Adv Prosthodont       Date:  2015-02-17       Impact factor: 1.904

2.  Influence of implant surface topography on primary stability in a standardized osteoporosis rabbit model study.

Authors:  Hiroshi Oue; Kazuya Doi; Yoshifumi Oki; Yusuke Makihara; Takayasu Kubo; Vittoria Perrotti; Adriano Piattelli; Yasumasa Akagawa; Kazuhiro Tsuga
Journal:  J Funct Biomater       Date:  2015-03-18

3.  Implant Stability of Biological Hydroxyapatites Used in Dentistry.

Authors:  Maria Piedad Ramírez Fernández; Sergio A Gehrke; Patricia Mazón; Jose L Calvo-Guirado; Piedad N De Aza
Journal:  Materials (Basel)       Date:  2017-06-12       Impact factor: 3.623

4.  Inhibition of cathepsin K promotes osseointegration of titanium implants in ovariectomised rats.

Authors:  Chun Yi; Ke-Yi Hao; Ting Ma; Ye Lin; Xi-Yuan Ge; Yu Zhang
Journal:  Sci Rep       Date:  2017-03-17       Impact factor: 4.379

5.  Correlation between Implant Geometry, Bone Density, and the Insertion Torque/Depth Integral: A Study on Bovine Ribs.

Authors:  Danilo Alessio Di Stefano; Paolo Arosio; Vittoria Perrotti; Giovanna Iezzi; Antonio Scarano; Adriano Piattelli
Journal:  Dent J (Basel)       Date:  2019-03-05

6.  Bone Density and Implant Primary Stability. A Study on Equine Bone Blocks.

Authors:  Francesco Orlando; Federico Arosio; Paolo Arosio; Danilo Alessio Di Stefano
Journal:  Dent J (Basel)       Date:  2019-07-01

Review 7.  Stability of Dental Implants and Thickness of Cortical Bone: Clinical Research and Future Perspectives. A Systematic Review.

Authors:  Danilo Alessio Di Stefano; Paolo Arosio; Paolo Capparè; Silvia Barbon; Enrico Felice Gherlone
Journal:  Materials (Basel)       Date:  2021-11-25       Impact factor: 3.623

8.  Primary implant stability in augmented sinuslift-sites after completed bone regeneration: a randomized controlled clinical study comparing four subantrally inserted biomaterials.

Authors:  Angelo Troedhan; Izabela Schlichting; Andreas Kurrek; Marcel Wainwright
Journal:  Sci Rep       Date:  2014-07-30       Impact factor: 4.379

9.  The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs.

Authors:  Danilo Alessio Di Stefano; Vittoria Perrotti; Gian Battista Greco; Claudia Cappucci; Paolo Arosio; Adriano Piattelli; Giovanna Iezzi
Journal:  J Adv Prosthodont       Date:  2018-06-12       Impact factor: 1.904

10.  Primary Stability of Dental Implants in Low-Density (10 and 20 pcf) Polyurethane Foam Blocks: Conical vs Cylindrical Implants.

Authors:  Luca Comuzzi; Margherita Tumedei; Ana Emilia Pontes; Adriano Piattelli; Giovanna Iezzi
Journal:  Int J Environ Res Public Health       Date:  2020-04-11       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.